Safety 2

Im portant  Safety 

Instructions

SAVE THESE INSTRUCTIONS - This manual 

contains important instructions that should be 

followed during installation, operation, and 

maintenance of the product. Save this manual 

for future reference.

 This is the safety alert symbol. When you 

see this symbol on your equipment or in this 

manual, look for one of the following signal 

words and be alert to the potential for personal 

injury!

 indicates a hazard which, if not 

avoided, will result in death or serious injury.

 indicates a hazard which, if not 

avoided, could result in death or serious injury.

 indicates a hazard which, 

if not avoided, could result in minor or 

moderate injury.
NOTICE addresses practices not related to 

personal injury.
Carefully read and follow all safety instructions 

in this manual and on tank and pump.
Keep safety labels in good condition. Replace 

missing or damaged safety labels.

 Risk of explosion. To prevent 

possible serious or fatal injury and/or damage 

to equipment, system pressure must be less than 

75 pounds per square inch (PSI) (517kPa) under 

any circumstances. Failure to follow instruction 

can result in tank blowup. If system discharge 

pressure can exceed 75 PSI (517kPa), install a 

relief valve capable of passing the full pump 

volume at 75 PSI (517kPa).

 Risk of freezing. Do not allow 

pump, tank, or piping system to freeze. Freezing 

can severely damage equipment and may lead 

to tank explosion and serious injury. Allowing 

tank to freeze voids tank warranty.
NOTICE Support the piping to and from the tank 

to prevent damage to the bottom tank fitting.
1.  Test well water for purity before using it.
2.  Disconnect power to pump and re lease 

all pressure in system be fore installing or 

servicing tank.

3.  Follow local codes when installing tank.
4.  Drain all water from system before performing 

any maintenance on tank.

Содержание CL42AW

Страница 1: ...950 Fax 1 800 526 3757 Web Site tractorsupply com 2011 CL707 11 21 11 Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 4 In...

Страница 2: ...eep safety labels in good condition Replace missing or damaged safety labels Risk of explosion To prevent possible serious or fatal injury and or damage to equipment system pressure must be less than...

Страница 3: ...ucts used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen servic...

Страница 4: ...leeder orifices are installed and operating correctly See sub mer sible pump owner s manual for more information NOTICE When using metal pipe with plastic fittings use only PTFE pipe thread sealant ta...

Страница 5: ...tantes o da adas Riesgo de explosi n Para impedir posibles heridas graves o fatales y o da os al equipo la presi n del sistema debe ser inferior a 75 lib pulg 517 kPa en todo momento La omisi n en el...

Страница 6: ...dos en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de Count...

Страница 7: ...accesorios de pl stico use solamente cinta sellante de PTFE para roscas de tuber a en las roscas macho Figura 2 Instalaci n t pica de una bomba sumergible Union Control Box 3 Wire Models Only Electric...

Страница 8: ......

Отзывы: