Country Flame Bayvue DV 30 Скачать руководство пользователя страница 7

 
Country Flame’s Bayvue DV stove must be vented vertically or horizontally through an outside wall.  This 
appliance and all its components are tested and safe to operate when installed in accordance with the 
instructions contained in this manual. Read and understand all instructions before beginning installation to 
ensure maximum efficiency and safety is achieved.  Failure to follow the instructions contained in this 
manual will void the warranty and may present a fire hazard.  Immediately, upon unpacking the product, 
report any glass or parts damaged, to both the shipping company and the local Country Flame Dealer. 

  

Country Flame

 

FIGURE 1:  BAYVUE DV DIMENSIONS 

 

ALTITUDE LIMITATIONS 

United States input ratings of this unit are based on sea level operation.  No appliance input rating needs to 
be changed for any operation at elevations up to 2000 feet (600m).  For operation at elevations above 2000 
feet, the Bayvue DV’s input rating shall be reduced at the rate of 4% for each 1000 feet above sea level.  
Exception:  As permitted by the authority having jurisdiction. 
 
Canadian input ratings of this unit are based on seal level operation.  No appliance input rating needs to be 
change up to 4500 feet above sea level in Canada.  Installation of this appliance at altitudes above 4500 
feet is subject to field test of the individual installation and approval by the local authority having 
jurisdiction. 
 

GAS SUPPLY CONNECTION 

Version 1.0h 

A gas supply line must be installed by a qualified professional and must conform to National Standards; 
NFPA 54 (natural gas) or NFPA 58 (propane) as well as local codes.  Connection of the gas supply line 
shall be made near the lower rear of the appliance.  The gas supply line shall be purged of air before 
connection is made to the appliance.  This shut-off valve must be located within 3 feet of the appliance or 
to the existing local code standard.  The Bayvue DV has been tested and approved for installation using a 
(7/8" O.D. / 1/2" I.D.)  Model #1650 N Dormont Flex Connector supplied with the unit.  REMEMBER: 
the gas supply line connection must be equipped with an easily visible shut-off valve.  Do not run gas 
supply lines through chimneys, gas vents, dumb waiters, elevator shafts, clothes chutes, or air ducts.  
Piping should be sloped ¼” for every 12 feet of horizontal run.  The slope will run from the gas meter 
down to the appliance and the horizontal run shall be supported every 10 feet by suitable gas pipe hangars 
or straps.  Install gas supply line drip leg traps where condensate might accumulate.  Sediment traps may 
be required by code.  Traps collect moisture and sediment that might block orifices or valves from 
operating properly.  Depending on the total length of gas supply line being run from the gas company 
meter to the appliance, different size piping is required.  Check with the local gas company for 
requirements but NEVER use plastic or galvanized pipe. 

Содержание Bayvue DV 30

Страница 1: ...his manual are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life IF YOU SMELL GAS FOR YOUR SAFETY Do not light any appliance Do not touch elec...

Страница 2: ...TS 14 NG CONVERSION KIT BV 3003 CONTENTS 14 PROPANE CONVERSION KIT 15 NATURAL GAS CONVERSION KIT 15 PROPANE CONVERSION 15 INTAKE AND EXHAUST CONDITIONS 18 SEALED VENTING SYSTEM 18 THERMOSTAT FAN CIRCU...

Страница 3: ...ON 36 GENERAL CLEANING 36 GENERAL SAFETY 36 GENERAL PERIODIC INSPECTIONS 36 CLEANING A PAINTED SURFACE 36 CLEANING PLATED SURFACES 37 DOOR INSTALLATION 37 DOOR SEAL 37 MAIN ORIFICES 38 GAS FLAME INSPE...

Страница 4: ...o hearing from you as this product becomes part of your home heating solution This manual is written to provide information that will assure proper installation proper maintenance and correct operatio...

Страница 5: ...d firing of the gas appliance At a minimum annually clean and repaint the interior surfaces to prevent deterioration More frequent cleaning may be required due to carpet lint bedding material dust etc...

Страница 6: ...MINIMUM CLEARANCES AND VENT AIR INTAKE PIPE CLEARANCES TABLE 1 BAYVUE DV SPECIFICATIONS BAYVUE DV 46 BAYVUE DV 30 NATURAL GAS PROPANE NATURAL GAS PROPANE Altitude 0 4500 0 4500 0 4500 0 4500 Manifold...

Страница 7: ...pproval by the local authority having jurisdiction GAS SUPPLY CONNECTION Version 1 0h 6 A gas supply line must be installed by a qualified professional and must conform to National Standards NFPA 54 n...

Страница 8: ...rates Turning the HI LOW valve to HI allows the appliance to operate at its maximum Btu output rating Turning the HI LOW valve to LOW allows the appliance to operate at its minimum Btu output rating...

Страница 9: ...ulator assembly within 3 feet 90cm horizontally from the center line of the regulator M 18 in Clearance under veranda porch deck or balcony 30 in minimum for vinyl clad soffits A vent shall not termin...

Страница 10: ...Other tools or equipment may be required depending on site specific conditions Various open end wrenches including 7 16 9 16 and crescent wrenches as needed Various nut drivers and torx drivers as req...

Страница 11: ...following steps present log installation instructions WARNING IMPROPER LOG PLACEMENT INSIDE THE FIREBOX CAN CAUSE IMPROPER FUEL BURN EXCESSIVE CARBON MONOXIDE a colorless odorless toxic gas PRODUCTIO...

Страница 12: ...rner is designed not only to hold the embers but also to produce a small flame that creates the burning ember effect The middle and rear burner are designed to produce the fire and turn the larger log...

Страница 13: ...REMOVAL From time to time it may be necessary to remove the valve assembly This assembly includes the SIT 820 control valve the base mounting plate for the burner assembly the pilot system the three b...

Страница 14: ...s instructions and all applicable codes and requirements of the authorized agency having juristriction If the information in these manufacturer s instructions are not followed exactly a fire explosio...

Страница 15: ...V 4623 55 DMS NG Front Orifice Spud Middle Spud Orifice 1 BV 4624 45 DMS NG Middle Orifice Spud Rear Spud Orifice 1 BV 4625 40 DMS NG Rear Orifice Spud Conversion Label 1 35 0500 02 Conversion LP to N...

Страница 16: ...r the correct gas pressures corresponding to the conversion kit being used WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructio...

Страница 17: ...riately sized drill bit as an air shutter gauge Pass the gauge through both sides of the air shutter adjust and lock the shutter removing the gauge when finished making adjustments STEP 11 Use a 3 8 i...

Страница 18: ...c igniter should be in a parallel plane to the pilot flame diffuser body Each time the igniter button is pressed a blue arc should occur from the piezoelectric igniter to the pilot flame diffuser body...

Страница 19: ...THE BATTERY ANNUALY SEALED VENTING SYSTEM The Bayvue DV is designed for a sealed vent system This means that all flue connections including all seams and joints are to be sealed with high temperature...

Страница 20: ...yvue DV product is approved for side wall vent or vertical vent through a roof Only Simpson Dura Vent chimney components or Selkirk Model Direct Temp chimney components may be used with this product S...

Страница 21: ...well as galvanized finish The galvanized pipe and fittings are used for concealed locations such as attics or spaces where corrosion is a factor such as above the roof line Decorative plated trim kits...

Страница 22: ...ermination 36 CF 11044 982 Snorkel Termination 14 CF 11040 984 Horizontal Square Termination CF 11041 983 Vertical Termination CF 11050 950 Vinyl Siding Standoff CF 11000 This standard termination kit...

Страница 23: ...eplace inside home air with fresh outside air so many times an hour This air exchange system is balanced to the number of occupants and the fuel burning appliances located in the home If additional co...

Страница 24: ...ed as an unrestricted space EXAMPLE 2 A room will have a direct vent fireplace installed that has an input rating of 26 200 Btu H An adjoining room connected by a doorless passageway contains a 60 000...

Страница 25: ...nting Graphs provided on the following pages will aid the installer in determining the proper relationship between vertical and horizontal side wall venting These Venting Graphs should assist the inst...

Страница 26: ...e center of the 10 inch square hole Attach the horizontal vent termination to the exterior wall with the four wood screws provided as shown in FIGURE 13 Before attaching the Vent Termination to the ex...

Страница 27: ...BLE Version 1 0h 26 HOT WOOD SCREWS Vinyl Siding Bolt Terminal to vinyl standoff Vinyl Siding Standoff Apply Sealant to all Four Sides Screws Wall Penetration Heat Shield Wall Thimble Duravent Part 94...

Страница 28: ...al rise required for a specific horizontal run FIGURE 17 HORIZONTAL VERTICAL VENT SYSTEM Version 1 0h 27 HORIZONTAL TOP FLUE INSTALLATION Round Support Box Wall Thimble Standard Horizontal Terminal 90...

Страница 29: ...rsection draw a vertical line to the bottom of the graph 4 Select the indicated dimension and position the unit in accordance with the same Example 1 Natural Gas Graph DV 46 If the vertical dimension...

Страница 30: ...MODEL DV 30 A vent shall not terminate A Within six feet 1 8 meters of a mechanical air supply inlet to a building B Above a utility meter within three feet 1 meter horizontally of its vertical center...

Страница 31: ...Bayvue DV appliance is 34 feet when measured from the top of the appliance to the bottom of the Flue Cap The maximum number of 45 degree elbows permitted for a vertical installation is four elbows In...

Страница 32: ...onto the top of the chimney system Note 1 For multi story vertical installations a ceiling fire stop Part 963 is required at the second floor and any subsequent floors The opening should be framed to...

Страница 33: ...ncy of homeowner use of this product Country Flame recommends that a certified service technician perform an annual check up on an appliance prior to the start of each heating season Follow the genera...

Страница 34: ...ttern or the pilot light flame pattern contact a local authorized Country Flame Dealer or certified technician FIGURE 21 STANDING PILOT GLASS CLEANING FREQUENCY Before the first use and after first fo...

Страница 35: ...eramic Kera Lite GLASS REPLACEMENT 1 Turn off gas valve 2 Unlock four door latches 2 each side refer to door installation section and FIGURE 23 WARNING Once door latches are unhooked nothing holds doo...

Страница 36: ...nt of rope cement to hold rope gasket in place 9 Reinstall assembly FIGURE 24 to stove body Close door latches securing assembly to Bayvue DV 10 The door assembly is a sealed unit Refer to door seal s...

Страница 37: ...working order No lubrication of any part is required in the Bayvue DV appliance It is recommended that at a minimum annual inspection of the venting system be conducted by a certified professional At...

Страница 38: ...rate the stove with the door open Correct Bayvue DV operation requires the door assembly be mounted to the stove and locked during all operations except during maintenance FIGURE 23 DOOR INSTALLATION...

Страница 39: ...ar When any one or all of the burners are removed ensure they are marked from the spot they were taken and returned to the same position The burners are NOT interchangeable and must be placed in the p...

Страница 40: ...irection of travel of the relief valve A spring provides tension to hold the relief valve against the body of the stove Relief plates should be free to slide on the tracks provided shown in FIGURE 26...

Страница 41: ...e pilot adjust or the manifold pressure can cause damage to the SIT 820 control valve and should only be accomplished by a certified professional For lighting instructions refer to the section on firs...

Страница 42: ...ovided by law All electrical components such as but not limited to blowers wiring switches speed controls thermo disc switches igniters burners and gas valves are covered under Country Flame Technolog...

Страница 43: ...ame is not large enough Pilot flame is not engulfing the generator thermocouple Thermocouple shorting Faulty valve Faulty thermocouple Purge the gas line Fill the tank Turn up the pilot flame Gently t...

Страница 44: ...gas pressure Remove and clean Adjust regulator Not heating properly Not enough or too slow Dirt in the burner orifice Wrong orifice Too much draft Improper gas pressure Underrated Appliance Remove an...

Страница 45: ...Orifice Spud Natural Gas 46 000 BTUH 45DMS BV 4625 Rear Orifice Spud Natural Gas 46 000 BTUH 40DMS BV 4626 Front Orifice Spud Liquid Propane 46 000 BTUH 69DMS BV 4627 Middle Orifice Spud Liquid Propan...

Страница 46: ...ard On Off Remote Kit GC 3934 Snap Disc Thermostat GC 3989 Ember Material All parts for the Bayvue DV product can be purchased by contacting a local authorized Country Flame Dealer In the event there...

Страница 47: ...turn the ON PILOT OFF control knob counterclockwise to ON 2 3 4 5 6 7 Turn off all electrical power to the Bayvue DV Open the Bayvue DV bottom panel to expose the gas control panel Push in on the ON P...

Страница 48: ...SAFETY LABEL Version 1 0h 47...

Отзывы: