Note.2
Note.3
±5.0% Typical adjustment by potentiometer.
Via V-Adj from PSU front panel)
±2.0% rated output voltage of single unit)
±1.0%
±1.0%
800ms, 100ms at full load
14ms / 230VAC at full load
90 ~ 264VAC, 127 ~ 370VDC (Refer to de-rating curve)
47 ~ 63Hz
33A / 115VAC, 65A / 230VAC
0.95 / 230VAC, 0.98 / 115VAC at full load
19.7A / 115VAC (2000W), 16.5A / 230VAC (3000W)
Note.4
Sele5V / 0.5A or +9V / 0.3A auxiliary output
By external switch
Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Adjustment of output voltage is between 0 ~ 105% of rated output
Adjustment of output current is between 0 ~ 105% of rated output
-20 ~ +60°C (Refer to de-rating curve)
20 ~ 90% RH non-condensing
-40 ~ +85°C, 10 ~ 95% RH
±0.02% / °C (0 ~ 50°C)
Load and temperature control fan
12V
200A
2400W
150mVp-p
15V
24V
30V
36V
48V
60V
160A
125A
100A
83.5A
62.5A
50A
2400W
3000W
3000W
3006W
3000W
3000W
< 3.5mA (240VAC)
10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6, IEC 60068-2-64
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25
/70%ΡΗ)
°C
Certified EN 55032
Certified EN 61000-3-2; EN 61000-3-3
Certified EN 55024; IEC 61000-4-2,3,4,5,6,8,11
Certified UL 60950-1; EN 60950-1
170x64x280 mm / 6.69x2.52x11.02 inch
3.9kg; 6pcs / 25.9kg / 2.48CUFT
88%
89%
91%
91%
92%
92%
93%
0~200A
0~160A
0~125A
0 ~ 100A
0 ~ 83.5A
0 ~ 62.5A
0 ~ 50A
105% rated output power
Note.6
Protection type: Constant current limit
Note.7
Please refer to page 5
Note.5
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7.
This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC
Variable OVP Refer to VCI VS OVP curve.(OVP Tolerance ±7%)
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Refer to pg. 5 for connection diagram)
85 5
±
°
C detect on NTC, Protection type: Auto recovery after temperature goes down
150mVp-p
240mVp-p
300mVp-p
360mVp-p
480mVp-p
600mVp-p
±3.0% rated output current of single unit)
REV. B9
19/01/17
1