background image

Warranty of COSTGUARD Filter Housings

This warranty applies to the Filter Housing. It does NOT appl

y to any disposable filter cartridge 

where life expectancy varies with the water being filtered. This warranty covers defects in the 

material and workmanship only for five full years from the original date or delivery. COST-

GUARD will replace any part which in COSTGUARD’s opinion is defective, unless: (1) any part 

of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, 

or (2) it has been repaired by anyone not approved by COSTGUARD. Our Obligation does not 
include the cost of shipment of materials. COSTGUARD is not responsible for damage in transit, 

and claims for such damage should be presented to the carrier by the customer.
This product has been designed solely for use as a housing for a disposable filter cartridge. It is 

NOT warranted against freezing, and neither this product nor its parts are warranted against 
defects or deterioration caused by uses for which the product was not expressly intended. THE 
FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EX

-

PRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OR TRADE OR COURSE 
OF DEALING, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR 
MERCHANTABILITY, THIS WARRANTY IS THE PURCHASER’S SOLE AND EXCLUSIVE 
REMEDY, IN NO EVENT SHALL COSTGUARD BE LIABLE FOR ANY ANTICIPATED OR LOST 
PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES 
OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS 
CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE 
PURCHASE, INSTALLATION, REPAIR OR FOR IT ANY LIABILITY OR TO MAKE ON ITS 
BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER 
HOUSING OR ANY PART THEREOF.

For servicing under this warranty, return any defective part to

 YOU DEALER within the five year 

period referred to above.

PERFORMANCE DATA

Important Notice: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment needs. 

It is 

recommended that, before installing a water treatment system, you have your water supply tested to determine your actual water treatment 

needs.
This 

system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the 

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving 

the system, as specified in NSF/ANSI 42/53.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems 

certified for cyst reduction may be used on disinfected waters that may contain filterable cyst.

OPERATING REQUIREMENTS

Pressure Range:

 30-125 psi (2.1-8.62 bar)

Temperature Range:

 40-100ºF (4.4-37.8ºC)

Turbidity:

 5 NTU Max.

TEST CONDITIONS

Flow Rate:

 As noted for each individual cartridge

Inlet Pressure: 

60 psi (4.1 bar)

Water Temperature:

 68º±5ºF (20º±2.5ºC)

Water pH:

 7.5±1

Installation instructions, parts and service availability, and 

standard warranty are inclosed with the product when 

shipped.
This drinking water system must be maintained accord-

ing to manufacturer’s instructions, including replacement 

or filter cartridges. Replace cartridges when capacity is 

reached, or when flow becomes too slow, but at least 

annually.

Model CGS-20

Substance 

Influent Challenge  Max. Permissible Product 

Reduction 

Average

 

Concentration 

Water Concentration 

Requirements  Reduction

CG53-20/CG53-20S Cartridge
Standard 42: Aesthetic Effects

Chlorine 

2.0 mg/L±10% 

 

>-50% 

97%

Particulates (0.5-<1µm) 

at least 10,000 

particles/ml 

>85% 

99%

Class 1 

 

 

Standard 53: Health Effects

Cysts* 

Minimum 50,000/> 

 

99.95% 

99.99%

Turbidity 

11±1 NTU 

0.5 NTU 

 

>95%

Flow Rate: 4.0 gpm (15.2) Lpm 

 

Capacity: 20,000 gallons (75,700L) or 12 months

CG5-20/CG5-20S Cartridge
Standard 42: Aesthetic Effects

Chlorine 

2.0 mg/L±10% 

 

>50% 

87%

Flow Rate: 

3.34 gpm (12.6 Lpm)

Capacity:

 12,000 gallons (45,400 L) or 12 months

*Based on the use of microspheres. Testing was performed under standard laboratory conditions, actual performance may vary.

The CGS-20 with CG53-20S cartridges are Tested and Certified 

by NSF International to NSF/ANSI Standard 42 for the reduction 
of Taste & Odor,  Aesthetic Chlorine, and Particulate. Standard 

53 - Cyst and Turbidity Reduction. CGS-20 with CG5-20 and 

CG5-20S cartridges are Tested and Certified by NSF International 
to NSF/ANSI Standard 42 for the reduction of Taste & Odor, and 
Aesthetic Chlorine.

Technical Support • Everpure: (800) 942-1153 • San Jamar: (800) 248-9826 • Mon-Fri., 8:00-5:00