24
ConteraIP Panoramic | Installation Manual
Alarm I/O Functions
Connect the Alarm In (DI) connector to the alarm input sensor, and connect Alarm Out (DO) connector to
the alarm output signal. To avoid any damaged, please follow the specification of the part as below:
Alarm In
(Dry Contact)
Alarm Out (Relay)
DC
AC
V sense
V sense
I sense
V sense
I sense
0.5V
0-220V
2A (max)
0-250V
2A (max)
Reset to Factory Default
1. Press and hold the reset button for 2 to 5 seconds and release the reset button. The camera has
been reset to the factory default except the network settings.
2. Press and hold the reset button for more than 5 seconds and release the reset button. The
camera has been reset to the factory.
3. Or, user can reset the camera to factory default via camera web interface or AV IP Utility