21
THE POWER CORDS MUST BE PROPERLY SPREAD OUT, SAFE FROM SHOCKS AND FAR FROM LIQUIDS,
WATER AND HEAT SOURCES, AND IN PERFECT CONDITION. THE USE OF ADAPTOR PLUGS IS FORBIDDEN.
Should it be absolutely necessary, only use approved adaptor plugs with earth connection.
Make sure that the available power supply voltage matches the values appearing on the rating plate of the
equipment. Consider also that the maximum allowable power voltage variation is +/-6%.
Before connecting, ensure that the power source impedance is in a module equal to or lower than 0,383 Ohm.
IMPORTANT: THE CABINET MUST BE PROPERLY CONNECTED TO THE EARTHING SYSTEM. Failure to meet
this safety provision invalidates whatever responsibility on the side of the manufacturer. If the equipment must
be installed far from the power points, make certain that the connection complies with the standards in force.
IMPORTANT: The cabinet needs a minimum free front space (1,5 mt) to allow use by purchasers and servicing
by the relevant personnel and also to ensure a suitable condenser cooling air volume. If the cabinet is instal-
led standalone, see that it has a clearance of 5cm all around for air circulation (see fig. 10 on page 13).The
cabinet was conceived solely to be installed against a wall or in a back-to-back unit.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMA-
GE ARISING FROM INCORRECT INSTALLATION.
6. TECHNICAL FEATURES
The built-in electrical installation is composed of control and safety devices lodged in the bottom section of the
cabinet. The relevant diagrams and part lists are contained in a sealed plastic envelope together with the pre-
sent instruction manual and must be keept with the latter. The cabinet technical details, which appear on the
plate affixed on the outside of the cabinet (see fig. 8 on page 12) are indicated on table III, page 12.
The BELUGA level generated by the cabinet under operation is below 55 dB(A). The cabinet does not genera-
te any harmful vibration.
WE HEREBY DECLARE THAT THE EQUIPMENT COMPLIES WITH ITALIAN DECREE LAW DATED 25/JAN/1992
N° 108 THAT IMPLEMENTS EEC DIRECTIVE 89/109 CONCERNING MATERIALS AND OBJECTS FIT FOR CON-
TACT WITH FOODSTUFFS.
We hereby declare that the cabinet is appropriate for the preservation of frozen food pursuant the provisions
in LAW No. 283 DATED 30/April/42 AND SUBSEQUENT AMENDMENTS, AND DECREE LAW OF 29/Jan/81
PUBLISHED IN THE OFFICIAL GAZETTE dated 26/MARCH/81 No. 85.
7. LOADING PRODUCTS
Switch the cabinet on using the wall cutoff switch. As soon as the cabinet is on it will start its cooling cycle.
Allow about 3 hours before loading any products, which must already be at their preservation temperature.
THE CABINET IS FACTORY-SET FOR THE ANTICIPATED PERFORMANCE.
When loading products make certain that:
• they are similar in size and type;
• they do not exceed the load limit line on fig. 13, page 11.
8. USE
This cabinet was designed and manufactured exclusively for the display of ice creams and deep frozen food