CA 8120 Instruction Manual 

 
                            

 

 

                          

         - 12 - 

Safety information 

 

The device is only designed as an alcohol breathalyser and may only be used 
for this purpose. 

 

Batteries may not be charged or reactivated and must be kept away from 
children. 

 

Medical attention must be sought immediately if a battery is swallowed.  

 

Only dispose of batteries at official or retail collection points. 

 

If you no longer want the device, please send it to your supplier. The supplier 
will ensure for proper recycling/disposal. 

Cleaning 

Only with a soft, dry cloth. Do not use cleaning agents. 

 
Technical information 

Display: 

4  digit  ( 0.000 ‰ ) 

Dimensions: 

W x L x D – 65 x 120 x 30 mm 

Weight: 

approx. 170 g incl. Battery 

Batteries: 

2 LR6 1.5 volt alkaline 

Measurement method:   Electrochemical sensor - police standard 
Precision: 

0,05‰  at  1.00 ‰ 

Measurement range: 

0.00 to 5‰ (0.00 to 2.50 mg/L) 

The C A 8120 should be recalibrated every 6  months. 

 

 
We reserve the right to make necessary technical and optical modifications and 
improvements without serving notice. 

 

Electrical and Electronic Equipment Act - ElektroG dated 16/03/05

 

Manufacturers and importers of these kinds of devices are required to dispose  

of them properly in accordance with statutory provisions. This alcohol breathalyser  

is a device subject above all to the provisions under § 2 / 8 and 9 of this law  

for which there is no requirement to make disposal at a public disposal  

site. – Your supplier would like however to comply with any future ordinances. 

 

Should you no longer use the device - we hope after many years of faithful  

serve - please return it to us so that we can dispose of it  

properly for you. - Thank you. 

Attachment / RoHS 

Содержание CA 8120

Страница 1: ......

Страница 2: ...8 Menu item Print 8 Menu item Device number 9 Menu item Limit 9 Menu item Languages 9 Menu item Password 10 Menu item Delete 10 Menu item Temperature 10 Menu item Calibration 10 Troubleshooting 11 Fo...

Страница 3: ...time of day and type passive active 5 Measurement result in a choice of 5 units mg L g L mg 100ml 6 Active or passive measurements 7 Wireless connection to mobile printer This allows immediate documen...

Страница 4: ...Germany criminal prosecution and a fine can be expected if neurological impairment is 0 30 or above A test with the C A 8120 will not be accepted by the police as evidence it is nevertheless an import...

Страница 5: ...int the result optional If you would like to perform a new test press Test If you select the Menu key the following appear Data Menu Off if you select Menu you have the choice between Time Unit Pressu...

Страница 6: ...90 seconds Performing a measurement Active measurement Turn the CA 8120 on with the key and press the key again to confirm Test The initiation of the warm up mode is indicated by Please wait The CA 8...

Страница 7: ...g following a measurement optional With the appearance of the measurement result in the display there is the option Print print out of the measurement result This option is only available if an option...

Страница 8: ...have updated the information confirm and save the updates with the Enter key Menu item Unit This menu item is password protected Following the correct input of the password the 5 different units prec...

Страница 9: ...ntered and confirmed numbers Confirming a second time with the Enter key following the selection of the last number saves the new device number Menu item Limit This menu item is password protected It...

Страница 10: ...e all of the measurement data confirm this with the Enter key If you do not wish to delete the measurement data return to the start screen with the C key Back Menu item Temperature This menu item is p...

Страница 11: ...n Used alkali batteries do not throw into fire do not charge batteries risk of explosion do not use force to open Risk of explosion Only dispose of as toxic waste Comply with local regulations governi...

Страница 12: ...method Electrochemical sensor police standard Precision 0 05 at 1 00 Measurement range 0 00 to 5 0 00 to 2 50 mg L The C A 8120 should be recalibrated every 6 months We reserve the right to make neces...

Страница 13: ...with accessories 1 piece 8200 195 00 Mouth pieces with rebreathing inhibitor 1 25 pieces packaged individually 1 piece 0023 to 100 units 0 30 to 1000 units 0 23 from 1000 units 0 19 Belt pouch for th...

Страница 14: ...e without authorisation from us Applicable EC guidelines Emissions Radiated emission EN55022 Interference immunity Electrostatic discharge EN61326 1 Electromagnetic field EN61326 1 Magnetic field powe...

Отзывы: