Electrical installation
Electrical Shock Hazard
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock
Only a qualified person in compliance with the instructions provided must install the
appliance.
The manufacturer declines all responsibility for improper installation, which may harm
persons and animals and damage property.
Important:
The power supply to the appliance must be cut off before any adjustments or maintenance
work is done on it.
Air duct is supposed to use in ventilation.
IMPORTANT:
Local Codes may vary; installation, electrical connections and grounding must comply with all
applicable local codes.
lf local codes permit grounding through the electrical supply neutral, connect both the white neutral
wire and the bare ground wire from the oven to the white neutral electrical supply wire.
All model ovens on the front cover are dual rated, designed to be connected to either 208/240V AC,
60Hz, 3 wire, two-phase power supply. (See Figure 3)
The electrical supply should be 3-wire two-phase AC. Install a suitable conduit box (not furnished).
An appropriately-sized, U-listed conduit connector must be used to correctly attach the conduit to the
junction box.
CIRCUIT REQUIRED
208V,60Hz
240V,60Hz
12 AMP
15 AMP
Figure 3