Declaration of Conformity and Safety
Standards

This product complies with the requirements

of Low Voltage

Directive (LVD) 73/23/EEC through the

harmonized standard EN 61010-1, 1993 + A1,

1992.

EMC Standards 

This product complies with the requirements

of EMC Directive 89/336/EEC through the

harmonized standards EN 50081-1 (emission)

and EN 50082-1 (immunity).

The CE symbol and corresponding declaration

of conformity are valid for the instrument

when any of the following apply:

• used as a standalone unit 

• connected to other CE-marked Cosmo Bio 

Co., Ltd., instruments

• connected to other products 

recommended or described in this manual 

• used in the same state as delivered from 

Cosmo Bio Co., Ltd., except for alterations 

described in this manual.

Description

Cat No.

Power Supply for i-MyRun

IMR-201

Electrophorsis Tank  for i-MyRun N

IMR-301

Gel Casting System for i-MyRun N

IMR-401

Support guide for Minigel (L&S)

IMR-501

Terms and Conditions of Sale

All goods and services are sold subject to the

terms and conditions of sale of the company

within the Cosmo Bio Co., Ltd., group that

supplies them. A copy of these terms and

conditions is available on request. 

Should you have any comments regarding this

product, we will be pleased to receive them at

the following address:

COSMO BIO CO., LTD. 

Toyo-Ekimae Bldg., 2-20, Toyo 2-Chome, Koto-

ku, Tokyo, Japan 135-0016

*For more information refer to page 6

1

Important user information

Please read this entire manual to fully understand and safely use the IMR-201.

The Warning sign highlights an instruction that must be strictly followed in order to

avoid personal injury. Do not to proceed until the instructions are clearly

understood and all stated conditions are met.

WARNING!

Standard Components

MyRunN/manual  04.10.28  10:48 AM  ページ3

Содержание i-MyRun.N

Страница 1: ...SMO BIO CO LTD Toyo Ekimae Bldg 2 20 Toyo 2 Chome Koto ku Tokyo 135 0016 Japan Tel 81 3 5632 9605 Fax 81 3 5632 9614 i MyRun N Instruction Manual Electrophoresis System MyRunN manual 04 10 28 10 48 AM...

Страница 2: ...IMR 201 Electrophorsis Tank for i MyRun N IMR 301 Gel Casting System for i MyRun N IMR 401 Support guide for Minigel L S IMR 501 Terms and Conditions of Sale All goods and services are sold subject t...

Страница 3: ...sed in the operation of this instrument as it can develop sufficient voltage and current to produce a lethal shock To avoid any risk of injury the instrument should only be operated by properly traine...

Страница 4: ...ld the power supply be connected to an electrophoresis unit that has a leakage path to earth the IMR 201 will detect this fault and the high voltage will be turned off 2 _Start current check To ensure...

Страница 5: ...e for use on six lanes A1 A6 1 _Make the gels by using the 26 tooth comb on six lanes A1 A6 2 _Set a gel with gel casting plate on the electrophoresis tank 3 _Set the guide over the plate 4 _Load the...

Страница 6: ...art of the gel unit with organic solvents such as ethanol or acetone 3 Power Supply Operation Check the Quick Start Operation Manual 1 _Insert the power supply connector into the electrophoresis tank...

Страница 7: ..._The display shows the last value of the selected and keys 3 _Select and adjust the running time by the selecting the key followed by 4 _Select If you do not wish to use the timer 1 _After selecting t...

Страница 8: ...centration is too high the temperature will increase rapidly If you want to withdraw the agarose gel from the support first cut the two small overhangs of agarose located at the end of the gel Note Re...