5 Cleaning
¡
If you need to clean the unit, please clean it under the following
conditions. Cleaning Method: lmmersion, Ultrasonic or Vapor
Cleaning Cleaning agent: IPA (Solvent type)
Cleaning Time: Within total 2 minutes for lmmersion, ultrasonic
and vapor cleaning
¡
Please dry the unit sufficiently after cleaning.
¡
If you do ultrasonic cleaning, please keep the ultrasonic output at
15W/ or below.
6 Temperature
Measuring Point
¡
It is necessary to note thermal fatigue life by power cycle.
Please reduce the temperature fluctuation range as much as pos-
sible when the up and down of temperature are frequently gener-
ated.
¡
Please have sufficient ventilation to keep the temperature of point
A in Fig.6.1 at Table6.1 or below. Please also make sure that the
ambient temperature does not exceed 85
C
.
Point A (Center of the Case)
Fig.6.1 Temperature Measuring Point on the case (Top View)
Table 6.1 Point A Temperature
Model
TUHS3 TUHS5 TUHS10
TUHS15
TUHS25
Output Voltage
ALL
ALL
ALL 12V, 24V 15V
ALL
Point A
105
C
105
C
105
C
100
C
95
C
100
C
Application manuals available at our website.
Recommended external components are also introduced for your
reference.
AC-DC Power Supplies PCB Mount Type
Instruction Manual
TUHS-20
June 26, 2020