background image

A

1.0 - 5.0

C

/s

A’

Ty1 : 160

20

C

Ty2 : 180

20

C

Ty1 - Ty2 : 120s max

B

1.0 - 5.0

C

/s

B’

Tp : Max 245

C

 10s max

Tx : 220

C

 or more : 70s max

C

1.0 - 5.0

C

/s

7  Safety Standards

6.2 Automatic Mounting (TYPE: B)

¡

To mount SU series automatically, use the transformer area near 
the center of the PCB as a pickup point.  To mount SUC series au-
tomatically, use the central area of the case as a pickup point.  If 
the bottom dead point of a suction nozzle is too low when mount-
ing, excessive force is applied to the transformer, which could 
cause damage.  Please mount carefully.
Please see the External View for details of the pickup point.

6.3 Soldering Conditions

(1) Reflow Soldering

¡

Fig.6.2 shows conditions for the reflow soldering for SU/SUC 

series.  Please make sure that the temperatures of pin terminals 
+Vin and -Vout shown in Fig.6.2 do not exceed the temperatures 
shown in Fig.6.3.

¡

If time or temperature of the reflow soldering goes beyond the 
conditions, reliability of internal components may be compromised.  
Please use the unit under the recommended reflow conditions.

¡

With this reflow profile, internal solder melts down.  When trans-
porting the unit within the reflow oven, please do not give vibration 
to the unit.

¡

Please avoid reflow soldering after applying adhesive or coating to 
the unit.

¡

You can reflow solder up to 2 times.  Do not reflow solder when 
the power supply is mounted on the back surface of the PCB be-
cause the unit may drop.

(2) Flow Soldering 

: 260

C

  

15 seconds or less

(3) Soldering Iron 

: maximum 360

C

  5 seconds or less

6.4 Stress to Pin Terminals

¡

If too much stress is applied to input/output pin terminals of the 
power supply, internal connection may come down.  If you apply 
stress as shown below, please kept it at 19.6N (2kgf) or less verti-
cally.

¡

Input/output pin terminals are soldered to the PCB internally.  Do 
not pull or bend a lead powerfully.

¡

If it is expected that stress is applied to the input/output pin ter-
minals due to vibration or impact, reduce the stress to the pin 
terminals by taking such measures as fixing the unit to the PCB by 
silicone rubber, etc.

6.5 Cleaning

¡

If you need to clean the unit, please clean it under the following 
conditions.
Cleaning Method: Varnishing, Ultrasonic or Vapor Cleaning
Cleaning agent: IPA (Solvent type)
Cleaning Time: Within total 2 minutes for varnishing, ultrasonic 
and vapor cleaning

¡

Please dry the unit sufficiently after cleaning.

¡

If you do ultrasonic cleaning, please keep the ultrasonic output at 
15W/  or below.

¡

To apply for a safety standard approval using the power supply, 
please meet the following conditions.  Please contact us for de-
tails.

¿

Please use the unit as a component of an end device.

¿

The area between the input and the output of the unit is isolated 

functionally.  Depending upon the input voltage, basic insulation, 
dual insulation or enhanced insulation may be needed.  In such 
case, please take care of it within the structure of your end-device.  
Please contact us for details.

On-board type

Instruction Manual

G-42

SU.SUC

On-board type

Instruction Manual

G-43

SU.SUC

Fig.6.4 Strength of Input/Output Pin Terminals

Fig.6.3 Recommend Reflow Soldering Conditions

+Vin

-Vout

Fig.6.2 Temperature Measuring Points when Setting Reflow Soldering Conditions 

(View from Above)

(

C

)

time(s)

Ty1

Ty2

Tp

Tx

A

A’

B

B’

C

19.6N(2kgf)

or less

19.6N(2kgf)

or less

19.6N(2kgf)

or less

19.6N(2kgf)

or less

Содержание SU/SUC10

Страница 1: ...es Yes Yes Double sided sided Single Yes Yes Yes Yes Series operation Basic Characteristics Data kHz glass fabric base epoxy resin Refer to Table1 2 Refer to Table1 2 Refer to Table1 2 Refer to Table1...

Страница 2: ...5 Remote ON OFF G 38 G 38 G 38 G 38 G 39 6 1 Installation 6 2 Automatic Mounting 6 3 Soldering Conditions 6 4 Stress to Pin Terminals 6 5 Cleaning G 41 G 42 G 42 G 42 G 42 6 Assembling and Installati...

Страница 3: ...tput voltages are adjusted simultaneously 2 Functions 2 1 Input Voltage Range If output voltage value doesn t fall within specifications a unit may not operate in accordance with specifications and or...

Страница 4: ...s less than the rated voltage Please see the following diagram for how to use the pin terminal RC When the pin terminal RC is at the Low level outflowing current is 0 5mA typ When Vcc is used please m...

Страница 5: ...ed any external capacitor However if you want to further reduce the output ripple noise connect an electrolytic capacitor or a ceramic capacitor Co to the output pin terminal as shown below If you use...

Страница 6: ...ion of the start up current Ip which flows when a DC DC converter starts up 6 Assembling and Installation 6 1 Installation You can install the units in any direction Place them in such a way that ther...

Страница 7: ...much stress is applied to input output pin terminals of the power supply internal connection may come down If you apply stress as shown below please kept it at 19 6N 2kgf or less verti cally Input out...

Страница 8: ...31205 SUCS32405 SUCS34805 SUCS30512 SUCS31212 SUCS32412 SUCS34812 SUCS30515 SUCS31215 SUCS32415 SUCS34815 SUCW30512 SUCW31212 SUCW32412 SUCW34812 SUCW30515 SUCW31215 SUCW32415 SUCW34815 SU SUC6 SUS605...

Страница 9: ...the ambient temperature does not ex ceed 85C 2 SUC3 In the case of forced air cooling please have sufficient ventilation to keep the temperature of point C in Fig 8 8 at 100C or below Please also make...

Страница 10: ...40C to the maximum temperature shown below 1 In the case of Convection Cooling On board type Instruction Manual G 45 SU SUC Fig 8 9 Derating Curve for Convection Cooling SU SUC6 Fig 8 10 Derating Cur...

Страница 11: ...mula Required electrolytic capacitor C can be obtained from the follow ing formula To Operate a Linear IC from 5V Output Power Supply On board type Instruction Manual G 46 SU SUC Fig 8 14 Derating Cu...

Страница 12: ...ollowing manner The unit can be used as a 24V type single output power supply as follows Another way to use the unit is described below The sum of 12V and 24V flows to the 0V line Please make sure tha...

Страница 13: ...ion SUXXXXXX SUOO3OOOOBP SUOO10OOOOBP SUOO6OOOOBP Material PET or PS Dimension in mm SUOO1R5OOOOBP OUT IN C12 30 27 24 21 18 15 12 9 6 29 26 23 20 17 14 11 8 5 28 25 22 19 16 13 10 7 4 3 2 1 1 C12 3 5...

Отзывы: