background image

AC-DC  Converters Value-added type

Instruction Manual

SNDPF-6

SNDPF

1 Terminal Connection

TB1

1
2
3

1

4

1

4

B

A

1 2

1

4

1

4

CN1

CN2

SW1

CN3

CN4

CN5

Fig.1.1 Terminal Connection

Table 1.1 Terminal connection and functions

No

Terminal 

connection

Function

1

AC(L)

AC Input

2

AC(N)

3

FG

FG

Table 1.2 Terminal connection and functions of CN1

Pin No.

Function

1

ENA-B  : Enable signal for SNDBS

2

-VOUT  : -DC output

3

NC 

: No connection

4

+VOUT  : +DC output

Table 1.3 Terminal connection and functions of CN2

Pin No.

Function

1

ENA-B/A : Enable signal for SNDHS

2

-VOUT  : -DC output

3

NC 

: No connection

4

+VOUT  : +DC output

Housing for protection is attached on CN2 at shipping from factory

Table 1.4 Terminal connection and functions CN3

Pin No.

Function

1

IOG  

: Inverter operation monitor

2

AUX : 

Auxiliary power supply for external signal

Table 1.5 Terminal connection and functions of CN4 and CN5

Pin No.

Function

1

C-AUX : 

 

Auxiliary power supply for external sig-

nal for synchronized  start up

2

C-ENA  : Enable signal for synchronized  start up

3

SG 

: Signal ground

4

CB 

: Current balance

Common signs among CN4 and CN5 represent the same potential.

Table 1.6 Mating connectors and terminals of CN1,CN2,CN3,CN4 and CN5

Connector

Mating 

connector

Terminal

Mfr.

CN1
CN2

B3P4-VH-B

VHR-4N

Reel  :SVH-21T-P1.1

Loose:BVH-21T-P1.1

J.S.T.

CN3

B2B-XH-AM

XHP-2

Reel  :SXH-001T-P0.6

Loose:BXH-001T-P0.6

CN4
CN5

B4B-XH-AM

XHP-4

Reel  :SXH-001T-P0.6

Loose:BXH-001T-P0.6

2  Input Voltage Derating

¡

Fig.2.1 shows rated output for each input voltage section.

  Maximum output should be within this range.

85

850

950

1000

1500

90 95

170

Input voltage [V]

Output power [W]

Fig.2.1 Input voltage derating curve

3 Standard Connection

 Method

3.1  Standard connection method

¡

To use SNDPF1000, connection shown in Fig.3.1 and outside at-

tached components are required.  Through this connection, DC output 

voltage can be obtained from AC input voltage.

  AC input voltage and DC output voltage are not insulated.

AC IN

FG

FG

FG

AC(L)

AC(N)

SNDPF1000

+V

-V

ENA

+V

-V

ENA (SNDBS)
RC1 (SNDHS)

SNDBS, SNDHS series

Fig.3.1 Standard connection method

OG UPFRHKPFF

 

Отзывы: