background image

1 Terminal Block

RMC-10

l

RMC15A

l

RMC30A

l

RMC50A

Frame ground
AC(L)
AC(N)
LED(+5V)
Output voltage adjustable potenti5V)

V1 Output
G1(V1)GND
V2 Output
G1(V2, V3)GND
V3 Output

2 Function

2.1 Input voltage range

n
n

n

The range is from AC85V to AC132V or DC110V to DC170V.

AC input voltage must have a rage from AC85V to AC132V for

normal operation. If the wrong input is applied, the unit will not op-

erate properly and/or may be damaged.

In cases that conform with safety standard, input voltage range is

AC100-AC120V(50/60Hz).

2.2 Inrush current limiting

2.3 Overcurrent protection

2.4 Overvoltage protection

n
n

n

n

n

n

Inrush current limiting is built-in.

If a switch on the input side is installed, it has to be the one han-

dling the input inrush current.

The thermistor is used for protection from inrush current. When

power is turned ON/OFF repeatedly within a short period of time,

it is necessary to have enough time for power supply to cool

down.

Overcurrent protection is built-in and comes into effect at over

105% of the rated current.

Overcurrent protection prevents the unit from short circuit and

overcurrent condition of less than 20 sec.

The unit automatically recovers when the fault condition is cleared.

The power supply which has a current foldback characteristics

may not start up when connected to nonlinear load such as lamp,

motor or constant current load. See the characteristics below.

Overvoltage protection circuit, clamping the output voltage by

zener diode, is built-in and comes into effect at over 115% of the

rated voltage. The unit in an overvoltage protection mode cannot

be recovered by a user; it must be repaired at the factory.

Overvoltage protection(diode)also comes into effect if the voltage

is externally applied to the output side.

Avoid applying voltage to the output side.

l

RMC15A

Model

RMC15A

RMC30A

RMC50A

Inrush current

20

30

30

Table 2.1 Inrush current

Unit:[A typ]

RMC

Fig. 2.1 Current foldback characteristics

Note: In case of nonlinear load, the output is locked out at A point.

: Load characteristics of power supply.

: Characteristics of load (lamp, motor, constant current load, etc.).

Load factor [%]

A

100

V

Output

volt

age

[V]

Instruction Manual

AC-DC Power Supplies Enclosed type

June 29, 2011

Содержание RMC15A

Страница 1: ...rated load input fuse 125V 3A 125V 3A 125V 2A Rated Basic Characteristics Data RMC50A RMC30A RMC15A Model 30 280 40 230 50 240 Flyback converter Flyback converter Flyback converter 1 3 0 8 0 4 frequency Switching Circuit method A current Input operation availability No No No Series Parallel Parallel operation Thermistor Thermistor Thermistor CEM 3 CEM 3 CEM 3 Yes Yes Yes 1 1 1 PCB Pattern Inrush p...

Страница 2: ...anual RMC 10 RMC 11 RMC 12 2 1 2 2 2 3 2 4 2 5 2 6 Input voltage range Installation method Inrush current limiting Derating Mounting screw Overcurrent protection Overvoltage protection Output voltage adjustment range Isolation RMC 10 RMC 10 RMC 10 RMC 10 RMC 11 RMC 11 RMC 11 RMC 11 RMC 11 RMC 12 RMC 10 RMC AC DC Power Supplies Enclosed type June 29 2011 ...

Страница 3: ...at over 105 of the rated current Overcurrent protection prevents the unit from short circuit and overcurrent condition of less than 20 sec The unit automatically recovers when the fault condition is cleared The power supply which has a current foldback characteristics may not start up when connected to nonlinear load such as lamp motor or constant current load See the characteristics below Overvol...

Страница 4: ...on between input output and output FG output terminals must be shorted 2 5 Output voltage adjustment range 2 6 Isolation 3 Series Operation and Parallel Operation n n n n Series operation with V2 and V3 is available by connecting the outputs of the unit as shown below Output current in series con nection should be lower than the lowest output current of the unit Series operation with other model i...

Страница 5: ...tments Keep isolation distance between screw and internal components as below chart 4 3 Mounting screw nPeak load current of V2 for RMC50A 1 is possible to draw 30 sec onds It will damage devices inside the power supply when the peak load current continues more than 30 seconds Model RMC15A RMC30A RMC50A 6 6 8 max Unit mm RMC Normal position Instruction Manual AC DC Power Supplies Enclosed type Jun...