Basic Characteristics Data

Basic Characteristics Data

Model

Circuit method

Switching

frequency

[kHz]

Input

current

[A]

Inrush

current

protection

PCB/Pattern

Series/Parallel

 operation availability

Material

Single

sided

Double

sided

Series

operation

Parallel

operation

Input module of

RBC200F

Active filter

40 - 220

2.4 

*

1

Relay

FR-4

-

Yes

No

No

Output module of

Y, Z

LLC resonant converter

90 - 180

-

-

FR-4

-

Yes

No

No

Output module of

G, H, J, K, L

Flyback converter

60 - 120

-

-

FR-4

-

Yes

Yes 

*

2

No

Output module of

M, P, Q

Flyback converter

60 - 120

-

-

FR-4

-

Yes

No

No

*

1

   The value at ACIN 100V and 200W output.

*

2

   Series operation is possible only if Slot 2 and Slot 3 are the same module. (Refer to Instruction Manual 3.1)

RB-6

Содержание RBC200F

Страница 1: ...Parallel operation Input module of RBC200F Active filter 40 220 2 4 1 Relay FR 4 Yes No No Output module of Y Z LLC resonant converter 90 180 FR 4 Yes No No Output module of G H J K L Flyback converte...

Страница 2: ...odel Name Construction RB 8 3 Series Operation and Parallel Operation RB 10 3 1 Series Operation RB 10 3 2 Parallel Operation RB 10 4 Assembling and Installation Method RB 10 5 Option and Others RB 12...

Страница 3: ...1 output is connected to V1 G1 Slot 2 output is connected to V2 V2 and G2 Slot 3 output is connected to V3 G3 Configuration rules 1 The code of the module installed in Slot 1 is selected from Slot 1 o...

Страница 4: ...tage protection circuit is built in If the overvoltage pro tection circuit is activated shut down the input voltage wait more than 3 minutes and turn on the AC input again to recover the out put volta...

Страница 5: ...ing on input voltage is shown in Fig 4 3 The definition of load factor is the following suffix k means the k th slot Ak Ik Vk Rated output power of k th module Rated output power Depends on input refe...

Страница 6: ...ing screw should be M3 The hatched area shows the allowance of metal parts for mounting 8 8 8 8 8 8 8 8 CN1 CN2 CN3 FG Fig 4 7 Allowance of metal for mounting If the power supply unit is fixed with me...

Страница 7: ...5 1 Table 5 4 and Table 5 5 Table 5 3 Maximum temperature of measurement points RBC200F O SN Installation condition Cooling Method Load factor Maximum temperature C 1 Capacitor 2 V1 Capacitor 3 V2 Ca...

Страница 8: ...y If you wire incorrectly the internal compo nents of a unit may be damaged T Option T units have vertically positioned screws on a terminal block The size specification is different from standard ver...

Отзывы: