PLA-10

Basic Characteristics Data

*

1

    The value of input current is at ACIN 100V and 90% load.

*

2

    Burst mode frequency is changed by the used condition. Please contact us about detail.

*

3

    Available by option -W.  Please refer to instruction manual "5. Option and Others".

Basic Characteristics Data

Model

Circuit method

Switching

frequency

[kHz]

Input

current

    

[A] 

*

1

Rated

input fuse

Inrush

current

protection

circuit

PCB/Pattern

Series/Parallel

operation availability

Material

Single

sided

Double

sided

Series

operation

Parallel

operation

PLA100F

Active fi lter

40 to 160

1.2

250V 3.15A

Thermistor

CEM-3

Yes

Yes

No

Flyback converter

20 to 150

 

*

2

PLA150F

Active fi lter

40 to 160

1.7

250V 4A

Thermistor

CEM-3

Yes

Yes

No

Flyback converter

20 to 150

 

*

2

PLA300F

Active fi lter

60

3.4

250V 10A

Thermistor

CEM-3

Yes

Yes

No

Forward converter

140

PLA600F

Active fi lter

60

6.7 250V 

16A

SCR

FR-4

Yes

Yes

*

3

Forward converter

220

PLA

me̲pla.indd   PLA-10

me pla indd PLA-10

2014/03/04   10:32:27

2014/03/04 10:32:27

Содержание PLA100F

Страница 1: ...ted input fuse Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation PLA100F Active filter 40 to 1...

Страница 2: ...on 1 4 Overvoltage Protection 1 5 Thermal Protection 1 6 Output Ripple and Ripple Noise 1 7 Output Voltage Adjustment 1 8 Isolation 1 9 Low Power Consumption 1 10 Remote ON OFF 1 11 Remote Sensing 1 1...

Страница 3: ...imary inrush cur rent and secondary inrush current will be generated because the thyristor technique is used for the inrush current limiting circuit 1 3 Overcurrent Protection An overcurrent protectio...

Страница 4: ...ial probe C1 Film capacitor 0 1 F C2 Aluminum electrolytic capacitor 22 F Fig 1 2 Measuring method of Ripple and Ripple Noise Remarks When GND cable of probe with flux of magnetic force from power sup...

Страница 5: ...ility of the unit periodic mainte nance of the fan is required Expected life of fan R t 90 is different by the used condition 2 2 Parallel Operation Redundancy operation is available by wiring as show...

Страница 6: ...Forced air 0 5m3 min 1Convection A mount 2Convection B C mount 0 8 0 10 0 6 0 4 0 5 0 2 20 10 Load factor C Ambient temperature Fig 3 3 Ambient temperature derating curve for PLA100F 150F 12 15 20 10...

Страница 7: ...e of fan AIR FLOW 20mm Measurement point Power supply Terminal block F A N Side AIR FLOW 20mm Measurement point Power supply Terminal block F A N Top Fig 3 8 Temperature of measurment point for fan li...

Страница 8: ...0F You can control output ON OFF in Option R units An external DC power supply is connected and it should be applied a volt age to a remote ON OFF connector to control it Appearance is changed from st...

Страница 9: ...ard model There is a lineup of optional harnesses Refer to option parts Please contact us for details Differences from standard versions are summarized in Table 5 6 Table 5 7 Specification differences...

Страница 10: ...on the model and the number of parallel operation Please contact us When output cable is not same length from each power supplies output current value will not be balanced at each units Please set the...

Страница 11: ...Please do not apply more than 5A per 1 pin Option J can not meet UL508 V ADJ AC L AC N FG V V CN1 CN2 Fig 5 15 Example of option J PLA100F Table 5 11 Mating connectors and terminals on CN1 and CN2 in...

Страница 12: ...e turning on the electricity and for a while after turning off please don t touch the inside of a power supply because there are some hot parts in that When a mass capacitor is connected with the outp...

Отзывы: