background image

1 Terminal Blocks

A-34

2 Functions

A-35

2.1  Input Voltage Range 
2.2  Inrush Current Limiting 
2.3  Overcurrent Protection  
2.4  Overvoltage Protection  
2.5  Thermal Protection 
2.6  Output Voltage Adjustment  
2.7  Remote ON/OFF 
2.8  Remote Sensing 
2.9  Alarms

3 Peak Current

A-38

4 Series/Parallel Operation

A-38

5 Assembling and Installation

A-40

A-35
A-35
A-35
A-35
A-36
A-36
A-36
A-37
A-38

4.1  Series Operation  
4.2  Parallel Operation/Master-slave Operation  
4.3  N+1 Parallel Redundancy Operation 

5.1  Installation
5.2  Derating
5.3   Expected Life and Warranty 

6 Others

A-42

6.1  Output Current Monitor
6.2  External Capacity
6.3  Isolation 
6.4  Auxiliary Power
6.5  External Component (Noise Filter) 

A-38
A-39
A-39

A-40
A-40
A-41

A-42
A-42
A-42
A-42
A-42

7 Options

A-43

7.1  Outline of Options

A-43

Unit type

A-33

PB

Instruction Manual

Содержание PBA1000F

Страница 1: ...bling and Installation A 40 A 35 A 35 A 35 A 35 A 36 A 36 A 36 A 37 A 38 4 1 Series Operation 4 2 Parallel Operation Master slave Operation 4 3 N 1 Parallel Redundancy Operation 5 1 Installation 5 2 D...

Страница 2: ...output 12V 0 1A RC1 Remote ON OFF AUXG Auxiliary output GND N C No connection PG Alarm PGG Alarm GND Matching connecters and terminals on CN1 CN2 and CN3 Connector Housing Terminal Mfr CN1 CN2 CN3 S1...

Страница 3: ...rcuit When you turn the power ON OFF repeatedly within a short period of time please have enough intervals so that the inrush current limiting circuit becomes operative When the switch of the input is...

Страница 4: ...1 gives you only an estimate Please contact us if you need accurate numbers Output voltage Xrated output voltage 1 Please do not apply an external voltage of 0 7V or less or 3 0V or more There is more...

Страница 5: ...ltage may dramatically fluctuate because of an imped ance of wiring and load conditions Please check and evaluate carefully before using the remote sensing function If the output voltage becomes unsta...

Страница 6: ...High vary depending on models and conditions PBA300F and PBA600F less than 1 second PBA1000F and PBA1500F less than 10 second 2If the output voltage is turned off through a remote ON OFF cir cuit the...

Страница 7: ...imum number of units you can use in parallel operation is 5 4 2 Parallel Operation Master slave Operation PBA10F PBA15F PBW15F PBA30F PBW30F PBA50F PBW50F PBA75F PBA100F and PBA150F You can use the po...

Страница 8: ...PBW30F Input Voltage Derating Curve Input voltage derating curve is shown in Fig 5 2 PBA300F PAB600F PBA1000F and PBA1500F Ambient Temperature Derating Curve Derating curve depending on an ambient te...

Страница 9: ...ting curve Unit type Instruction Manual A 41 PB Fig 5 3 Ambient temperature derating curve Ambient temperature C Load factor 80 70 80 90 100 30 40 50 60 70 71C 0 10 20 30 40 50 60 20 10 20 0 10 Fig 5...

Страница 10: ...filter Examples of Constant Values of the External Noise Filter L1 0 45mH L2 0 45mH C1 0 1 F C2 0 1 F C3 0 1 F C4 4700pF C5 4700pF R1 2MW R2 2MW 6 Others 6 1 Output Current Monitor PBA300F PBA600F PB...

Страница 11: ...ns Doing so may cause a failure F1 PBA600F PBA1000F PBA1500F Option F1 units have a longer life fan instead of a standard fan This option is not available for PBA300F Differences from standard version...

Страница 12: ...PBW30F PBA50F and PBW50F 2 Matching Molex Connectors and Terminals for PBA75F PBA100F and PBA150F R PBA50F PBW50F PBA75F PBA100F and PBA150F You can control output ON OFF remotely in Option R units To...

Страница 13: ...5F and PBA30F has been filed Safety agency approvals will be void if the cover is attached after the unit is ex factoried N1 PBA10F PBA15F PBW15F PBA30F PBW30F PBA50F PBW50F PBA75F PBA100F and PBA150F...

Отзывы: