background image

4.1 Installation method

n

n

n

n

When two or more power supplies are used side by side, position

them with proper intervals to allow enough air ventilation. Ambient

temperature around each power supply should not exceed the

temperature range shown in derating curve.

Please be carefull with that metal parts do not touch mounted

parts at front side, where major components are mounted, when

a power supply is installed with them.

The operative ambient temperature is different by with/without

case cover or mounting position. Please refer drawings as below.

Valid ambient temperature is different depending on the use of

the cover or the mounting positions. Please refer to the following

derating curve.

When unit mounted except below drawings, it is required to con-

sider ventilated environment by forced air cooling for tempera-

ture/load derating. For details, please consult our sales or engi-

neering departments.

4.2 Derating

LCA-20

When the output voltage is more than 12V.

D1 D2: Please use Schottky Barrier Diode

(b)

n
n

Parallel operation is not possible.

Redundancy operation is available by wiring as shown below.

n

n

Even a slight difference in output voltage can affect the balance

between the values of I and I .

Please make sure that the value of I does not exceed the rated

current of a power supply.

I

the rated current value

(a)

1

2

3

3

Series operation is available by connecting the output of two or

more power supplies, as shown below. Output current in series

connection should be lower than the lowest rated current in each

unit.

l

LCA50S LCA75S LCA100S LCA150S

4 Assembling and

Installation Method

(b)

n
n

Parallel operation is not possible.

Redundancy operation is available by wiring as shown below.

n

Even a slight difference in output voltage can affect the balance

between the values of I and I .

Please make sure that the value of I does not exceed the rated

current of a power supply.

I

the rated current value

1

2

3

3

LCA

I

2

I

1

I

3

-

-

+

Power
Supply

Power
Supply

+

Load

I

2

I

1

I

3

-

-

+

Power
Supply

Power
Supply

+

Load

Load

Load

Power
Supply

+

Power
Supply

-

-

+

Load

Load

Power
Supply

+

Power
Supply

-

-

+

+

-

+

-

Power
Supply

Power
Supply

Load

D1

D2

Power
Supply

+

-

Load

Power
Supply

+

-

Instruction Manual

AC-DC Power Supplies Open Frame/Enclosed type

June 29, 2011

Содержание LCA10S

Страница 1: ...rcuit method Flyback converter Flyback converter Flyback converter A 1 3 0 7 0 4 0 3 current Input 200 3 3 2 2 A Fuse operation availability 1 1 1 1 1 1 1 Series Parallel Parallel operation Thermistor...

Страница 2: ...2 1 2 2 2 3 2 4 2 5 Input voltage range Installation method Inrush current limiting Derating Overcurrent protection Overvoltage protection Output voltage adjustment range LCA 18 LCA 18 LCA 19 LCA 19 L...

Страница 3: ...If the wrong input is ap plied the unit will not operate properly and or may be damaged Inrush current limiting is built in If a switch in the input side is installed it has to be the one han dling th...

Страница 4: ...case of nonlinear load the output is locked out at A point Load characteristics of power supply Characteristics of load lamp motor constant current load etc l l l LCA50S LCA75S LCA100S LCA150S LCA10S...

Страница 5: ...n Parallel operation is not possible Redundancy operation is available by wiring as shown below n n Even a slight difference in output voltage can affect the balance between the values of I and I Ple...

Страница 6: ...mperature Load factor Ambient temperature Convection Forced air 0 5m min 3 Convection Forced air 0 5m min 3 A F mounting A F mounting E F mounting A B C D mounting 10 100 80 60 40 20 0 70 60 50 40 30...

Страница 7: ...t FG terminal to safety ground of the unit lLCA150S F mounting should be operated by Forced air Note In the hatched area the specification of Ripple Ripple Noise is different from other area lLCA15S L...

Отзывы: