7. Adjustment
1) Resistance can be adjusted by tension control to increase or decrease the exercise
intensity.
2) After a long-term use, the turning parts may be loose, please tighten the bolts or screws
following the instruction of the engineman.
8. Maintenance and Treatment
1) Verify that all the bolts and nuts are locked properly and the turning parts should be
turned freely without damaged parts.
2) Clean the equipment with soap and slightly damp cloth only. Please do not use any
solvent to clean the equipment.
Malfunctions and treatment
Malfunction Reason
Treatment
Base is unstable
1. Floor is not flat or there is
Small object under the front or
Rear stabilizer.
2. The front and rear base feet
have not been leveled when
assembling.
1. Remove the object.
2.Adjust the front and rear stabilizers.
Handlebar or seat
cushion is shaking.
The screw loose.
Tighten the screws.
Loud noise from
the moving parts.
The interval of the parts has not
been tightened correctly.
Open the covers to check.
No resistance when
using the
equipment.
1.The interval of the magnetic
resistance increases.
2. Tension control is damaged.
3. Running belt is slip.
1. Open the covers to check.
2. Replace the Tension control.
3. Open the covers to check.