CT1001/CT1002 Touchscreen Programmable Thermostat
Installer Setup
Name
Settings
Notes
Initial
Setting
Record
Date
(Year Upper)
Select first two digits of current calendar year
(20 for year 2001-2099)
.
It cannot be changed.
Date
(Year Lower)
Select last two digits of current calendar year (08 for
year 2008, etc).
2001 - 2099 available.
Date (Month)
Select number that represents current calendar
month.
Date (Day)
Select number that represents current calendar
date.
Schedule Options
0-nonprogrammable.
4-7-day programmable.
When it is changed, the
Schedule must be
reprogrammed.
System Type
Selection
1-1 heat/1 cool conventional (factory setting).
2-single-stage heat pump (no auxiliary heat).
3-heat only conventional (no fan) Also for 750mV.
4-heat only conventional (with fan).
5-heat only (power to open and power to close zone
valves or normally-open zone valves).
6-cool only conventional.
7-2 heat/1 cool heat pump (with auxiliary heat).
8-2 heat/2 cool multistage conventional.
9-2 heat/1 cool multistage conventional.
10-1 heat/2 cool multistage conventional.
11-2 heat/2cool heat pump (no auxiliary heat).
12-3 heat/2cool heat pump (with auxiliary heat).
Available options and
defaults vary by thermostat.
System selection
automatically modifies some
default settings and/or hides
other Installer Setup options.
50
Table 3. Installer Setup Menu.
NOTE
:
For easier installer setup, write the selected options in the "INITIAL SETTING RECORD" column.