Control mode
In control mode, it is determined whether drying
should occur continuously (MAN - manual mode) or is
only to be activated when necessary, on the basis of
the ambient climate.
The selected control mode is displayed in the lower,
left-hand corner in standard view.
Open the screen for selecting control mode by pressing
the upper, right-hand button.
The following basic control modes are available:
MAN
Manual, continuous drying.
RH
Dehumidification for selectable relative
humidity (%).
X
Dehumidification for selectable mixing
ratio (g/kg).
DP
Dehumidification for selectable dew point
(°C).
HYG
Dehumidification is controlled by an
external hygrostat that is connected to
the machine.
Thanks to its network functions, you can also connect
the machine to external temp. and RH sensors, and use
their values to control operation, instead of the built-in
sensor for relative humidity and temperature. The
following modes for external sensors exist for this
purpose:
E.RH
Dehumidification for selectable relative
humidity (%) according to the input
values from the external temp and RF
sensor(s) that are connected to the
machine.
E.X
Dehumidification for selectable mixing
ratio (g/kg), according to the input values
from the external sensor(s) that are
connected to the machine.
E.DP
Dehumidification for selectable dew point
(°C), according to the input values from
the external sensor(s) that are connected
to the machine.
The external control mode requires that the machine is
network connected and connected to an external temp.
and RH sensor. If the machine is not already connected