Fault finding
Symptom
Probable cause
Action
The machine is
showing “Power
Supply Failure” alarm.
There is no power in the
outlet used with power
cable no. 2.
Check that power cable no. 2 is connected.
Check the fuse to see that power is available
through the outlet.
The machine is
showing “All
temperature sensors
have failed” alarm.
The temperature sensor
assembly is not properly
connected.
The sensor assembly is
damaged.
Connect temperature sensor assembly to the
machine.
Replace or repair sensor assembly.
Note: If one or several of the temperature
sensors have failed, the machine will
continue to operate until manually switched
off, regardless of whether it is in Auto or
Man (Manual) mode.