ORDINARY MAINTENANCE
- 31
ORIGINAL INSTRUCTIONS
7
ORDINARY MAINTENANCE
General warnings
7.1
DANGER
Before carrying out any maintenance operations, you must turn off the machine and unplug the power supply
cable from the mains socket outlet.
During machine maintenance operations there is a high risk of contact with the coloring product; strictly fol
-
low the indications of chapter 2.2.
Maintenance table
7.2
WARNING
The frequencies indicated are approximate, since they depend on the type of colorants, environment condi-
tions and frequency of use of the machine.
Operations
Accessories
Frequency
beginning
of shift
twice a
week
when
necessary
Initialize and purge machine
Clean the nozzle center
Check the sponge is clean
Check the sponge is saturated
without humidifier system
Moisten the sponge
without humidifier system
Clean the sponge
Clean the dispenser externally
Fill up the humidifier system bottle
with humidifier system for water-based
colorants
Products to be used
7.3
We recommend to use products compatible with the type of colorants in the machine when cleaning the nozzle
center and moistening the humidifier cap sponge.
Type of colorant
Suggested product
Solvent-based colorants
slow-evaporating solvent, compatible with the colorants used
Water-based colorants
water
Mixed systems
the choice depends on the type of vehicles used to produce the colorants; for
more information, contact the dealer or colorant manufacturer.
Should growths form in the Autocap, in the sponges or in the humidifier system water bottle, it is advisable to
use the following fluids:
Propylene glycol solution, 50% by volume, in water;
•
AgCl solution in water;
•
Bleach (dilution 1%).
•