 11.0  Limited  Warranty

Corning Incorporated (Corning) warrants that this product will be free 
from defects in material and workmanship for a period of two (2) years 
from date of purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES 
WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES 
OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s 
sole obligation shall be to repair or replace, at its option, any product or 
part thereof that proves defective in material or workmanship within 
the warranty period, provided the purchaser notifies Corning of any such 
defect. Corning is not liable for any incidental or consequential damages, 
commercial loss, or any other damages from the use of this product. 
This warranty is valid only if the product is used for its intended purpose 
and within the guidelines specified in the supplied instruction manual. 
This warranty does not cover damage caused by accident, neglect, misuse, 
improper service, natural forces, or other causes not arising from defects 
in original material or workmanship. This warranty does not cover motor 
brushes, fuses, light bulbs, batteries, or damage to paint or finish. Claims for 
transit damage should be filed with the transportation carrier. 
In the event this product fails within the specified period of time because of 
a defect in material or workmanship, contact Corning Customer Service at: 
USA/Canada 1.800.492.1110, outside the U.S. +1.978.442.2200, visit 
www.corning.com/lifesciences

, or contact your local support office. 

Corning Customer Service will help arrange local service where available 
or coordinate a return authorization number and shipping instructions. 
Products received without proper authorization will be returned. All items 
returned for service should be sent postage prepaid in the original packaging 
or other suitable carton, padded to avoid damage. Corning will not be 
responsible for damage incurred by improper packaging. Corning may elect 
for onsite service for larger equipment. 
Some states do not allow limitation on the length of implied warranties 
or the exclusion or limitation of incidental or consequential damages. 
This warranty gives you specific legal rights. You may have other rights 
which vary from state to state. 
No individual may accept for, or on behalf of Corning, any other obligation 
of liability, or extend the period of this warranty.
For your reference, make a note of the model number, serial number, date 
of purchase, and supplier here. 

Model No.  ________________________   Date Purchased _________________________
Serial No.  _________________________  Supplier _______________________________

 

Содержание PC-170

Страница 1: ...tes and PC 171 Stirrer Instruction Manual Catalog Numbers Hot Plates Model No PC 170 6795 170 120V 6797 170 100V Stirrer Model No PC 171 6795 171 120V This manual is available in additional languages at www corning com lifesciences ...

Страница 2: ...Product Description 3 3 0 Operating Conditions 3 4 0 Warnings 4 5 0 Heating Operation and Controls 4 6 0 Stirring Operation and Controls 4 7 0 Inspection Procedure 5 8 0 Preventive Maintenance 5 9 0 Technical Specifications 5 10 0 Technical Support Service 5 11 0 Limited Warranty 6 12 0 Equipment Disposal 7 ...

Страница 3: ... D Corning Scholar PC 170 Hot Plate Enameled 5 x 5 in 12 7 x 12 7 cm 4 x 5 x 5 in 10 2 x 12 7 x 12 7 cm Corning Scholar PC 171 Stirrer Plastic 5 x 5 in 12 7 x 12 7 cm 3 2 x 5 x 5 in 8 1 x 12 7 x 12 7 cm 3 0 Operating Conditions The Corning Scholar Hot Plates and Stirrer are designed to be safe when used under the following conditions Indoor use Altitude up to 2 000 meters Temperature of 0 C to 40 ...

Страница 4: ...damage may occur 5 0 Heating Operation and Controls To operate the unit turn the dial until the dial indicator lines up with the desired dial setting The Corning Scholar PC 170 Hot Plate will not heat when the dial setting is turned to the OFF position The following table details approximate temperatures for various dial settings Dial Setting Approx Temp C Low 60 2 100 3 140 4 160 5 200 6 230 High...

Страница 5: ...e use Contact Corning for additional instructions regarding interior spills 9 0 Technical Specifications Cat No Model Power Temp Range Stir Range rpm 6795 170 PC 170 Hot Plate 120V 50 60Hz 250W 2 1A 60 C to 360 C N A 6797 170 PC 170 Hot Plate 100V 50 60Hz 250W 2 5A 60 C to 360 C N A 6795 171 PC 171 Stirrer 120V 50 60Hz 30W 0 25A N A 100 to 1 600 10 0 Technical Support Service If you have a questio...

Страница 6: ...d be filed with the transportation carrier In the event this product fails within the specified period of time because of a defect in material or workmanship contact Corning Customer Service at USA Canada 1 800 492 1110 outside the U S 1 978 442 2200 visit www corning com lifesciences or contact your local support office Corning Customer Service will help arrange local service where available or c...

Страница 7: ...ended the Corning Scholar PC 170 Hot Plates and Corning Scholar PC 171 Stirrer are marked with the crossed out wheeled bin and must not be disposed of with domestic waste Consequently the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment WEEE provided with the products and available at the following link www corning com weee ...

Страница 8: ... 3 3586 1291 Korea t 82 2 796 9500 f 82 2 796 9300 Singapore t 65 6572 9740 f 65 6735 2913 Taiwan t 886 2 2716 0338 f 886 2 2516 7500 EUROPE CSEurope corning com France t 0800 916 882 f 0800 918 636 Germany t 0800 101 1153 f 0800 101 2427 The Netherlands t 020 655 79 28 f 020 659 76 73 United Kingdom t 0800 376 8660 f 0800 279 1117 All Other European Countries t 31 0 206 59 60 51 f 31 0 206 59 76 ...

Отзывы: