Preface Material  

MA1000 Installation and Configuration Guide 

23 

4.3.1.1

 

Wall Mount 

MA1000 RHU  is usually mounted on a wall in a clean indoor environment –  RF ports facing 
down
.  

Assembly instructions 

1.  Place the unit against the wall and mark the four holes to be drilled in the wall. 
2.  Drill four holes 8mm in diameter and insert the appropriate sized plastic plugs in each hole. 
3.  Secure the MA1000 RHU to the wall using four screws, 4.5mm diameter, 40mm long. 
 
 
 

 

Figure 17. MA1000 RHU Wall Mount 

4.3.1.2

 

Connections 

NOTE: Keep in mind the rules for handling and connecting F/O cables. The F/O cables will be 
connected to the associated BU in the communication room at a later phase.  

1.  Connect fiber optic cable to splice box and to SC/APC pigtails to RHU. 
2.  For the downlink, connect the fiber optic cable pigtails from splice box coming from the BU 

port to the corresponding RHU port. 

3.  Connect the RHU to antennas according to the RF engineers design (up to 4 antennas per 

RHU). 

4.  For the uplink, connect the fiber optic cable pigtails from splice box from the RHU to the 

uplink port that connects to the BU

5.  Connect the power to each RHU according to power design planning. 
6.  Verify that 50 ohm terminators are placed on the unused uplink and downlink connectors. 
  

Содержание MobileAccess1000

Страница 1: ...MobileAccess1000 DAS System Installation and Configuration Guide P N 709C001504 REV A0 Date AUG 2012...

Страница 2: ...Installation and Configuration Guide II Corning MobileAccess 8391 Old Courthouse Road Suite 300 Vienna VA 22182 Tel 1 866 436 9266 1 703 848 0200 TAC 1 800 787 1266 Fax 1 703 848 0280 www corning com...

Страница 3: ...lation needs to be implemented in such a way so as to ensure RF radiation safety levels and non environmental pollution during operation Caution Use of controls or adjustments or performance of proced...

Страница 4: ...fiber optic connector should not come into contact with any object or dust Refer to the cleaning procedure for information on the cleaning of the fiber tip Power Requirements for DC Inputs Warning On...

Страница 5: ...structions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one...

Страница 6: ...are included in your system installation P N Description 709C001503 1000 Installation and Configuration Guide 709C001205 2000 Installation and Configuration Guide 709C002502 RIU Installation and Conf...

Страница 7: ...Acronyms VI Table of Contents VII 1 Introduction to MA1000 System 1 1 1 About MA1000 1 1 1 1 Features 1 1 2 System Architecture 1 1 3 Configuration Options 3 1 4 Management 4 2 System Elements 5 2 1...

Страница 8: ...19 4 2 4 Multi Building Rack Installation 20 4 2 5 RIU Connections 21 4 2 6 BU Connections 21 4 2 7 Controller Connections 21 4 3 Remote Site Installation 22 4 3 1 MA1000 RHU Installation 22 4 3 1 1 W...

Страница 9: ...Preface MA1000 Installation and Configuration Guide IX MA1000 TSX 33 Base Units 33 Remote Hub Unit Modules 34 Add On Modules 34 Power Supply Accessories 35 Mounting Bracket Accessories 35...

Страница 10: ...s optimal performance for all services Local and remote end to end monitoring and control through an interface to 410 430 or SC 450 system controller Low power system requirements eliminates the need...

Страница 11: ...the following devices Radio Interface Units RIUs The RIUs provide interfaces for up to three BTS BDA signals and automatically adjusts the output signal in response to input signal level in order to p...

Страница 12: ...d MA 1000 RHU The dual band RHU consists of a low band service cellular 800 iDEN Paging or GSM 900 and a high band service PCS 1900 or DCS 1800 Figure 2 MA1000 Basic BU RHU Configuration B Using the A...

Страница 13: ...S 232 or dial up connection Management access is provided through the MCT GUI application or via the NMS Server Software Application which communicates via SNMP over a Ethernet TCP IP connection The 4...

Страница 14: ...site and the supported services The following sections describe each of the system elements NOTE The connections as they relate to the MA 1000 system are described in Chapter 4 System Installation 2 1...

Страница 15: ...nfrastructure through the 1000 RHU antenna ports However if 860 WLAN solution is also installed the combined data and voice services are fed to the coax infrastructure through the 860 antenna ports NO...

Страница 16: ...service which is combined with the RHU services and distributed through the common coax infrastructure DL UL Transmit the RF signals to and from the Add on module These ports are connected to the cor...

Страница 17: ...U Add on Front panels Table 2 3 Corning MOBILEACCESS Add on Front Panel Indicators LED Description RUN When blinking indicates that the RHU is in normal operating mode PWR Power ON 2 1 2 2 Add on Rear...

Страница 18: ...High port 2 2 Base Units The BUs Base Units perform RF to optical conversion of the signal on the BTS BDA side Each can support up to two services provided by the same operator Two models of BUs are...

Страница 19: ...or Link 5 to Link 8 Figure 9 Eight Port BU Front Panel Figure 10 Four Port BU Front Panel Table 2 5 BU Front Panel Indicators LED Description PWR Power input detected for the corresponding unit LSR O...

Страница 20: ...a four port BU one uplink and one downlink port is connected for an eight port BU two uplink and two downlink ports are connected Figure 11 BU Rear Panel RF Connections Table 2 6 BU Rear Panel Connec...

Страница 21: ...to the specific installation 3 3 Coaxial Cable Connections 3 3 1 General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area...

Страница 22: ...amond p n ENC 1045342 Black Brown boots 1Meter MA 50000105 Diamond p n ENC 1045343 Black Brown boots 3 Meter MA 500001060 Zipcord patchcord 4xSC APC 62 5 125 900 2000 4500 micron Diamond p n ENC 10453...

Страница 23: ...equivalent for checking coax cables including the antennas 2 The VSWR must be measured prior to terminating the RHUs in the remote communication rooms Terminate all unused RHU and RIU ports with a 50...

Страница 24: ...on a wall depending on your configuration 3 5 Installation Conventions Some of the basic installation conventions are listed below for the 1000 system Base Units are usually concentrated in the same...

Страница 25: ...ividual units By providing power from a single distribution point maintenance can be reduced and UPS backup can be easily provided The maximum distance from the source to the termination spot is 1000...

Страница 26: ...communication room close to the RF signal source This installation may differ between single and multi building topologies B Remote locations RHU and Add on installations and connections These are usu...

Страница 27: ...on is for a single operator If the site is serviced by more than one operator each operator often installs their equipment in a separate rack NOTE Note that the 410 430 SC 450 Controller is at eye lev...

Страница 28: ...and around the installed components so that the safety of the equipment is not compromised It is recommended to allow for at least about 2 cm of airspace between devices in the rack Verify that the eq...

Страница 29: ...ng 1 installation in a remote location with several Base Units For clarity the example shows two Base Units However the configuration applies to a maximum of four 8 port Base Units that are supported...

Страница 30: ...ar the BUs 1 Connect 3 125 900 pigtail with SC APC connectors between splice tray and patch panel cabinet 2 Connect 3 125 3000 SC APC jumpers between the corresponding BU and patch panel 3 Connect the...

Страница 31: ...ation Guide 22 4 3 Remote Site Installation 4 3 1 MA1000 RHU Installation Mount and install each RHU on the wall in the communication shaft or communication room The following provides the dimensions...

Страница 32: ...the rules for handling and connecting F O cables The F O cables will be connected to the associated BU in the communication room at a later phase 1 Connect fiber optic cable to splice box and to SC A...

Страница 33: ...Preface Material MA1000 Installation and Configuration Guide 24 4 3 2 Add on Installation The following figure provides the dimensions for the Add On unit Figure 18 Add On Dimensions...

Страница 34: ...32 NC screws 2 Position the RHU Add on unit on the bracket and secure the Add on to the bracket using the four supplied 8 32 screws 3 Interconnect the 1000 RHU and RHU Add on SMA Uplink Downlink and...

Страница 35: ...Refer to the corresponding User Manual for detailed instructions on installing the unit 4 3 4 Antenna Connections For systems without the 860 WLAN solution modules connect the antenna connections to t...

Страница 36: ...Low Band Services LTE SISO 698 716 777 787MHz 728 757MHz CELL 824 849 869 894 Telstra 850M 824 849 869 890 iDEN SMR800 806 824 851 869 GSM 890 915 935 960 E GSM 880 915 925 960 iDEN SMR900 Paging 896...

Страница 37: ...72 68 74 Max Intermod Distortion dBm 13 13 36 13 Max NF dB 20 20 20 16 16 Gain Flatness Ripple dB 3 1 05 1 5 WCDMA compiles with 3GPP TS 25 106 V5 0 0 2002 03 table 9 4 spectrum emission mask Out of b...

Страница 38: ...dBm AGC ON Min 3 3 3 SFDR2 dB 65 67 70 65 66 64 66 Max Intermod Distortion dBm 30 13 13 13 13 Max NF dB 18 18 18 Gain Flatness Ripple dB 3 2 0 WCDMA compiles with 3GPP TS 25 106 V5 0 0 2002 03 table...

Страница 39: ...Unit and Remote hub must be multimode capable All fiber in a given length of fiber must be of the same core diameter All Bulkhead adapters must be single mode SC APC Green adapters All terminations cr...

Страница 40: ...tic connections Remote Management Controller SNMP NMS via connection to the MA 410 MA 430 or SC 450 Physical Characteristics Dimensions WxDxH 19 x 8 x 1 74 482 6x203 2x17 4mm Weight 3 Kg 6 6 lb Mounti...

Страница 41: ...pported Services Single service corresponding to the model Power Input power 25 48VDC Power Consumption 50W RF Connections To RHU SMA 50 ohm Remote Management SNMP NMS via RHU connection Physical Char...

Страница 42: ...ELL PCS and AWS 1000M C85P19A17 A MA1000 TSX tri service CELL PCS and AWS with MMF IDEN SMR PCS 1000 IDEN SMR G PCS MA1000 TSX tri service iDEN SMR and PCS with G Block support 1000M IDEN SMR G PCS MA...

Страница 43: ...00 GSMO DCS4E Dual band GSM orange DCS 4 ports UMTS Add on support 1000M iDEN SMR MMF dual band iDEN SMR800 SMR900 Paging 4 ports PCS Add on support 1000 iDEN SMR4 Dual band iDEN SMR800 SMR900 4 ports...

Страница 44: ...100W Power Supplies European Connector AK PWR CORD UK AC Power Cord for 66W and 100W Power Supplies UK Connector Mounting Bracket Accessories Part Number Description BRKT 1200 STK Bracket for stackin...

Отзывы: