Ground
Note: Ground according to local regulations
The following additional (not supplied) tools and components are required for connecting the system ground:
•
Grounding wire - grounding wire should be sized according to local and national installation
requirements. The provided grounding lug supports 14 AWG to 10 AWG stranded copper (or 12 AWG to
10 AWG solid) wire conductors.
1.
Use a wire-stripping tool to remove approximately 0.4 inch (10.9 mm) of the covering from the end of
the grounding wire
2.
Insert the stripped end of the grounding wire into the open end of the grounding lug
3.
Crimp the grounding wire in the barrel of the grounding lug. Verify that the ground wire is securely
attached to the ground lug by holding the ground lug and gently pulling on the ground wire
4.
Prepare the other end of the grounding wire and connect it to an appropriate grounding point at the site
to ensure adequate earth ground