2.1.3
Mount the DRU in the 19’’
Rack
1.
Determine the location of the DRU in the rack while considering additional units (e.g. power supply).
2.
Position the two brackets located on the DRU sides to fit in to the rack rail.
3.
Slide the DRU module into the selected slot on the 19” chassis rear. Ensure the module is flush with the
chassis rear.
Ensure
at least 2” distance between the ventilation openings (in the rear and sides of the DRU) and any
object (e.g. wall)
4.
Secure the unit’s rack ears to the rack frame, via applicable bracket holes, using the appropriate nuts and
screws. using 2 screws in each side.
2.1.4
Connect the Cables
2.1.4.1
Ground
1.
Connect one side of the grounding cable to the DRU rear grounding point and secure with 4 mm screw
and washer.
2.
Connect the other side of the grounding cable to grounding.
Screw to
chassis
Grounding
point