Standard Recommended Procedure 003-1002-AEN | Issue 7 | January 2019 | Page 23 of 25
6.2 Replace EDGE8™ Module
Step 1:
Open front door and pull tray out.
Step 2:
Press latch on LC connector and pull connector out (Figure 34). If jumper is equipped with MTP
®
connector, simply grasp connector body and pull connector out of the adapter. (
NOTE:
only LC
connectors shown in Figure 34.)
Step 3:
Press lever on right side of module and pull module out.
Step 4:
Unplug MTP connector(s) in rear of module.
Step 5:
Reverse process to install new module (or panel, if upgrading the network).
Figure 34 — Replace EDGE8™ Module
6.3 Remove Trunk Cable
6.3.1 Cable in Keyhole Cradle
If necessary to replace trunk cable or keyhole cradle, remove per the directions in this section (Figure 35). Install
new cable or cradle per the directions in Section 4.4.
Step 1:
Pull back on both latches while pushing cradle in opposite direction. Lift cradle and cable up.
Step 2:
Open cradle door.
Step 3:
Lift furcation plug out of the cradle.
Figure 35 — Remove Trunk Cable in Keyhole Cradle