Wiring Change Instruction from 230V to 208V 3 Phase Operator
FS EP Series
3. Completed.
FS-EP-3P-V02
Y
R
FOR 230V
R
FOR 2
08V
PWR
Y
R
FOR 230V
R
FOR 2
08V
PWR
Y
R
FOR 230V
R
FOR 2
08V
PWR
R
R Y
REMOVE (FACTORY INSTALLED FOR 230V)
Y
CONNECT (FOR 208V)
R
Y
R
Insulate
the wire
R
R
BK
1L1
BK
BK
1L1
BK
1L1
1L1
1L1
1. Unplug the red "230V" wire connector from the red "PWR" wire
connector.
Remove the insulating cap from the yellow "208V" wire connector.
2. Put t
he insulating cap on the red "230V" wire connector.
Plug the yellow "208V" wire connector into the red "PWR" wire
connector.