![CornellCookson FS-150EP Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/cornellcookson/fs-150ep-series/fs-150ep-series_installation-instructions-and-operation-manual_2668463008.webp)
7
FS-150EP Series
230V, 50Hz
REVISION # 0000
DATE: 02/18/2021
WIRING INSTRUCTIONS
Disconnect power at the fuse box before proceeding with any wiring.
1. Do not install any wiring or attempt to run this operator without checking the wiring diagram located
on the inside of the control box cover.
2. Do not turn on power until you have finished making all power and control wiring connections.
3. Do not run power and control wiring in the same conduit.
4. Any wire connected to the control panel must be protected by conduit or other means to ensure the
safety and permanency of the wiring.
5. Use copper wire inside the control panel.
6. A separate fuse line of adequate capacity is needed for the operator.
7. The operator must be properly grounded. The ground screw, painted green, is located inside the
control panel.
8. For an operator, system, or external device requiring field installed wiring between a Class 2 output
of an operator and an external device, the type of wiring shall be R/C (AVLV2/8), AWM, min. 22
AWG, rated 60°C, with VW-1/FT2.
Failure to properly ground the operator could result in electric shock and
death or serious injury.
Unless the operator includes an internal lock sensing system, or external
electrical interlocks are installed, remove or make all door locks inoperative,
or secure locks in the unlocked position. Failure to disable the locks could
result in damage to the door or operator.
WARNING
WARNING
WARNING
Содержание FS-150EP Series
Страница 16: ...FS 150EP Series 230V 50Hz REVISION 0000 DATE 02 18 2021 15 ...
Страница 17: ...FS 150EP Series 230V 50Hz REVISION 0000 DATE 02 18 2021 16 ...
Страница 18: ...FS 150EP Series 230V 50Hz REVISION 0000 DATE 02 18 2021 17 NOTE ...
Страница 19: ...FS 150EP Series 230V 50Hz REVISION 0000 DATE 02 18 2021 18 NOTE ...
Страница 27: ...FS 150EP Series 230V 50Hz REVISION 0000 DATE 02 18 2021 26 APPENDIX 4 1 NO 2 OFF ON PK PK ...