background image

Cornell Communications, Inc 

4800 Design Guide 10-20-16

 

 

Cautions and Warnings 

 

The following Manual is to be used as a guide to install the 4800 Emergency Communication System. Consult 
your local “Authority Having Jurisdiction” for required code compliance and installation standards.  The 

Caution

 and 

Warning

 symbols are placed throughout this manual to identify critical requirements for a safe 

and proper installation. 
 

 

 

1. Caution - 

The 4800 Digital Emergency Communication System requires installation by factory trained 

authorized dealers/distributors, in accordance with ANSI/NFPA 70 National Electrical Code. 
 

2. Caution 

-

 

Properly trained personnel, familiar with Telecommunications Industry Associations 568 TIA/EIA 

standard, are required for proper installation. Failure to terminate the wiring correctly will cause damage to the 
system and void the warranty. 
 

3. Caution - 

The 4800 Digital Emergency Communication System shall be installed in a controlled, indoor dry 

environment, with temperatures maintained between 55°F and 95°F. 

 
4. Caution - 

The 4800 Digital Emergency Communication System requires an 

Analog “POTS”

 dedicated 

telephone line for “Offsite” modem communication.

 

 
 
 
 
1. Warning – 

Cornell Communications manufactures proprietary Control Panels and Switches that have 8 

available RJ45 ports to connect to additional Remote Control Panels, Switches and Call Stations. These devices 
connect using the straight-thru, TIA/EIA 568A or TIA/EIA 568B, wiring standard. Any attempt to connect an 
“Off the Shelf” Ethernet switch will damage the system and void all warranty! 
 

2. Warning – 

The 4800 Digital Emergency Communication System requires installation by factory trained 

authorized dealers/distributors, in accordance with NFPA 70 National Electrical Code, by qualified electricians. 
The 4800 System meets FCC 15, Subpart A, Section A (Commercial Use) emissions and is ICES-003 (Canada) 
compliant, when installed according to the installation instructions and the state/local electrical codes. 
Component or device substitutions such as Power Supplies, Switches or required cabling types are not 
permissible. 

 
3. Warning -  

Failure to comply with the installation instructions, the NEC, NFPA and local building code will 

void all agency listings and warranty coverage. 
 

4. Warning -  

Control Panels, Expansion Switches, Call Stations and Power Supplies require EMI suppression 

filters, to be added to the field wire connections during installation, for FCC compliance. Refer to page 16 of the 
4800 Installation Manual.

 

 
5. Warning -  

To ensure proper operation, the 4800 system should be tested on a regular basis by qualified 

personnel. 

 

 

 

 

 

 

Содержание 4800 series

Страница 1: ...Emergency Communication System Series 4800 Design Guide Cornell Communications Inc Milwaukee WI 53223 USA 800 558 8957 ...

Страница 2: ...e of Contents 2 Cautions and Warnings 3 System Components 4 5 4800 System Riser 6 System Layout Options 7 8 Dedicated Phone Line Connection 9 VoIP Phone Line Connection 10 Cell Phone Line Connection 11 System Configuration 12 Signage 13 Maintenance 14 Warranty Returns Agency approvals 15 ...

Страница 3: ...tions manufactures proprietary Control Panels and Switches that have 8 available RJ45 ports to connect to additional Remote Control Panels Switches and Call Stations These devices connect using the straight thru TIA EIA 568A or TIA EIA 568B wiring standard Any attempt to connect an Off the Shelf Ethernet switch will damage the system and void all warranty 2 Warning The 4800 Digital Emergency Commu...

Страница 4: ... of 2 UL FCC compliant 24VDC battery back up power supplies listed below Each Power Supply can support the approximate number of devices as shown Larger systems will require the use of multiple Power Supplies based on the Call Station count and building layout The Power Supplies and Expansion Switches are surface mount units that are required to be located in a controlled Maintenance Phone room en...

Страница 5: ...Cornell Communications Inc 4800 Design Guide 10 20 16 5 System Components ...

Страница 6: ...Cornell Communications Inc 4800 Design Guide 10 20 16 6 ...

Страница 7: ...xtra attention to the additional 13 15 vertical rise per floor Cable Type Use Maximum Limitation Cat5e Ethernet Cable Control Panel Expansion Switch Call Station 100 M or 328 2 16AWG UL 24VDC Power Supply 478 2 22AWG UL Batt AC Fault Detect 2000 The 3 system examples below utilize the basic layout information that should be applied to all system designs Caution The power supplies B 5243B or B 5248...

Страница 8: ... Control Panel RCP connection The Remote Control Panel RCP has 1 7 Call Stations and 1 Expansion Switch ES connection The Expansion Switch ES can support up to 8 Call Stations CS or a combination of Control Panels Expansion Switches and Call Stations These are just a few small scale examples of the 4800 system capabilities For large capacity applications questions or concerns please contact your C...

Страница 9: ...izure capability If the 4800 system is required to share a phone line with another device an RJ31X jack must be installed as illustrated below Proper installation of the RJ31X jack will allow the 4800 system to Seize the shared analog POTS line and place an emergency call to the assigned monitoring location 1 Connect a standard straight thru Cat5e cable from the RJ31X jack to the J7 port on the Co...

Страница 10: ...od of offsite voice connection if the phone service internal external network or power system fails the 4800 system will not be able to connect to the offsite monitoring location The example VoIP service disclaimers below are generally included with service contracts Several manufacturers offer analog voice phone adapters Please confirm with the current prospect VoIP service for the correct certif...

Страница 11: ...k or power system fails the 4800 system will not be able to connect to the offsite monitoring location The example Cellular service disclaimers below are generally included with service contracts The 4800 system phone line circuit is checked every 24 hours for proper operation A notification of a fault will be shown on the Control Panel s display in the event of a failure You may experience interr...

Страница 12: ...d below MODEL QTY A 4800M Main Control Panel 1 BB 48 Flush Mount Enclosure 1 A 4800R Remote Control Panel 1 4 BB 48 Flush Mount Enclosure 1 for each A 4800R required 4800V Call Stations 1 255 ES 4808 Expansion Switch 1 32 BB 49 Surface Mount Enclosure 1 for each A 4800R required B 5243B 3 3 Amp Power Supply Supports 22 Call Stations B 5248A 8 Amp Power Supply Supports 50 Call Stations Comment ____...

Страница 13: ... Electric A C Single Face illuminated 9 5 H x 13 75 W x 1 7 D _______ SN E42D Electric A C Double Face illuminated 9 5 H x 13 75 W x 1 7 D For Electric only Add R for Area of Refuge Add M for metal Electric Edge Lit _______ SN B48DG Electric A C Double Refuge Battery Backup 11 H x 13 W x 2 D _______ SN B48SL Electric A C Double Rescue Battery Backup 11 H x 13 W x 2 D _______ SN LM42S Radiance Phot...

Страница 14: ...tion the 4800 system should be tested on a regular basis by qualified personnel Power Supply Maintenance Each Unit should be tested at least once a year for the proper operation as follows Output Voltage Test Under normal load conditions the DC output voltage should be checked for proper voltage level 24VDC Battery Test Under normal load conditions check that the battery is fully charged check spe...

Страница 15: ...ther warranty expressed or implied will ting by the factory 36 month Warranty does not apply to 3rd Party OEM products which carry the original manufacturer s warranty Please verify OEM warranty with your Cornell Regional ns will be accepted with RMA for no cost Defective materials will be repaired for a minimum and cost of the repair will be for time and materials not to exceed the cost of a new ...

Отзывы: