Continuous Flow ICemaker Service Manual

© 2005-2014, Cornelius Inc.

- 4 -

Publication Number: 630460308SER

B

IN

 C

ONTROL

The type of bin control used on all WCC & WCF Models is an electronic control. The control is supplied with power to 
terminals X1 and X2. Terminals X3 and X4 are a normally closed switch which open when the thermostat sensor bulb 
senses ice.

The sensing element is located in a 5/16” stainless steel tube which hangs from the dispense tray cover down through 
the center of the drop tube.

To test switch, start the icemaker and block the outlet tube. When the ice fills the drop tube about 1/2 full the icemaker 
should shut off. When tube is cleared the ice maker should restart within 5 min.

The Bin control is in electrical series with coil on antifreeze relay along with the low water safety. If unit is water cooled, 
the condenser high pressure cut out is also in series.

The Control Switch is held in place inside electrical box by 2 screws. The Control bulb is in the drop tube. It can be 
removed by pulling the cable located on the top of the dispense tray cover. When replacing the sensor make sure the 
bulb is inserted to the bottom of the thermostat well.

G

EAR

 

MOTOR

The gearmotor is equipped with a start relay and a manual reset overload.

When current is applied, the relay energizes and completes the circuit to the start winding. The motor reaches a 
predetermined speed and the relay drops out, disconnecting the start winding. The run winding remains in the circuit 
as long as current is applied.

The purpose of the overload is to automatically shut off the motor in the event of a mechanical bind of the 
transmission, an overload condition within the evaporator or an electrical malfunction. It does this by sensing 
amperage draw. If the motor stalls the start relay would energize and stay energized. The amperage would surge 5 to 
6 times greater than the normal draw. In this event the overload would shut off the transmission in 4 to 8 seconds.

If the motor is subjected to an abnormal load, but does not reach a stall condition, the overload will react, but over a 
greater period of time. The reaction time depends upon the amperage to which it is subjected.

The overload, through the safety circuit, also shuts off the compressor.

Содержание WCC 2001 QT-R

Страница 1: ...EMAKER WCC 2001 QT R Service Manual Release Date September 21 2005 Publication Number 630460308SER Revision Date March 18 2014 Revision G Visit the Cornelius web site at www cornelius com for all your...

Страница 2: ...ccurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alterat...

Страница 3: ...ntenance 5 Monthly 5 Quarterly 5 Semi Annually 6 Water Level Control 7 How Water Level Control Works 7 Purpose 7 To Replace Water Level Control 7 To Replace Water Level Safety Switch 7 Electrical 8 Te...

Страница 4: ...Upper Nut and Bearing Assembly 14 To Replace Bearing 14 Electrical Checkout 14 Overload Check 15 Compressor Check 15 Capacitor Check 15 Safety Controls 16 Guide to Good Ice 17...

Страница 5: ...oderate injury or equipment damage SAFETY TIPS Carefully readandfollowall safety messagesinthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnhowt...

Страница 6: ...y or equipment damage SHIPPING AND STORAGE CAUTION Before shipping storing or relocating the unit the unit must be sanitized and all sanitizing solution must be drained from the system A freezing ambi...

Страница 7: ...data for continuous flow icemaker series 500 700 1000 and 2000 SPECIFICATION CHART Models Condensing Unit VAC HZ PH Wire Comp RLA Fan Amps GRMTR Amps Refrigerant Circuit Fuse Oz Type WCC2001 R Remote...

Страница 8: ...cable located on the top of the dispense tray cover When replacing the sensor make sure the bulb is inserted to the bottom of the thermostat well GEAR MOTOR The gearmotor is equipped with a start rela...

Страница 9: ...rature water 2 minute exposure time 10 Sanitize auger diverter assembly and ice transition drop tube in a sink using sanitizing solution and reinstall in icemaker Using sanitizer wipe down the dispens...

Страница 10: ...icemaker water seal 2 Check drain tubes for clogs and aged tubes Replace if tubes are stained or brittle 3 Check for signs of condensation Clean where necessary and replace insulation properly 4 Check...

Страница 11: ...only provides a visible check of water level but also is a good guide to the internal conditions which exist within the icemaker assembly itself See Cleaning Procedure TO REPLACE WATER LEVEL CONTROL...

Страница 12: ...Continuous Flow ICemaker Service Manual 2005 2014 Cornelius Inc 8 Publication Number 630460308SER ELECTRICAL Figure 3 Schematic and Wiring Diagram WCC2001 QT R...

Страница 13: ...the pressure charts you can easily determine whether or not the expansion valve is working properly ADJUSTMENT AND TROUBLESHOOTING When troubleshooting the expansion valve you must first be sure you h...

Страница 14: ...Turn screw counterclockwise to raise opening point or clockwise to lower opening point Opening point of valve should be set to maintain proper operating pressure in refrigeration system high side Ref...

Страница 15: ...Continuous Flow Icemaker Service Manual Publication Number 630460308SER 11 2005 2014 Cornelius Inc...

Страница 16: ...ntinuity replace the relay Figure 6 Gearmotor Assembly TO REPLACE GEARMOTOR ASSEMBLY WARNING Disconnect power to the unit before servicing Follow all lock out tag out procedures established by the use...

Страница 17: ...the output shaft seal Push down on the washer com pressing the spring on the output shaft seal While holding the seals down in place slide the E ring into the groove on the output shaft Figure 7 Shaf...

Страница 18: ...The bearings are 3 32 thick When they wear below 1 16 they should be replaced Bearings to be inspected for wear during quarterly maintenance To Replace Bearing WARNING Disconnect power to the unit bef...

Страница 19: ...he compres sor if there is no continuity as the run windings are open 2 Check between C and S Replace the compres sor if there is no continuity as the start windings are open 3 Check between C and R o...

Страница 20: ...unit to function The safety and control system shut off devices are 1 Low water shut off reed switch located in icemaker float assembly Automatic reset type 2 Gearmotor thermal overload manual reset t...

Страница 21: ...Continuous Flow Icemaker Service Manual Publication Number 630460308SER 17 2005 2014 Cornelius Inc GUIDE TO GOOD ICE...

Страница 22: ...Continuous Flow ICemaker Service Manual 2005 2014 Cornelius Inc 18 Publication Number 630460308SER Figure 14 Troubleshooting Chart...

Страница 23: ......

Страница 24: ...Cornelius Inc www cornelius com...

Отзывы: