- 3 -

Publication Number: 621360241LOEWOP

M

OUNTING

 

IN

 

OR

 

ON

 

A

 C

OUNTER

!

WARNING:

When installing the unit in or on a counter top, the counter must be able to support a weight in excess of 450 lbs.

 

to insure 

adequate support for the unit. 

FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT 

DAMAGE.

NOTE:  Many units incorporate the use of additional equipment such as ice makers. When any 

addition equipment is used you must check with the equipment manufacturer to 
determine the additional weight the counter will need to support to ensure a safe 
installation.

C

ART

 I

NFORMATION

 

AND

 M

OUNTING

The Viper unit may be mounted on a mobile cart (Cornelius part no. 620043075 for 2-barrel unit, 620053990 for 3-
barrel unit and 620046556 for 4-barrel unit) which allows some movement of the unit for service and cleaning. There 
are four captive nuts on the bottom of the Viper to accommodate four 3/8-16 bolts. These bolts must be installed to 
secure the unit to the cart.

These carts are also designed with movable wheels that act as outriggers to provide stability to the unit when it is 
being moved.

!

WARNING:

The above listed mounting bolts must be installed and the wheels extended and locked in the outboard position prior to moving 
the unit.

FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE.

THE APPLIANCE HAS TO BE PLACED IN A HORIZONTAL POSITION.

Содержание Viper Elite

Страница 1: ...OVERRUN Operator s Manual Release Date October 26 2015 Publication Number 621360241LOEWOP Revision Date January 09 2017 Revision C Visit the Cornelius web site at www cornelius com for all your Liter...

Страница 2: ...g occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alte...

Страница 3: ...trol System Overview 4 Beginning Operation 4 Basic Operation 5 Dispensed Product Throughput 6 Barrel Status Lights 6 Control Panel Display 6 Control Panel menu Buttons 7 Replenishing Supplies 8 Syrup...

Страница 4: ...Specifications 14...

Страница 5: ...equipment damage CAUTION Indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury or equipment damage SAFETY TIPS Carefully read and follow all safety me...

Страница 6: ...ea around the unit clean and free of clutter FAILURE TO KEEP THIS AREA CLEAN MAY RESULT IN INJURY OR EQUIPMENT DAMAGE SHIPPING AND STORAGE WARNING Do not use dispense spigot to lift or move unit as th...

Страница 7: ...on CART INFORMATION AND MOUNTING The Viper unit may be mounted on a mobile cart Cornelius part no 620043075 for 2 barrel unit 620053990 for 3 barrel unit and 620046556 for 4 barrel unit which allows s...

Страница 8: ...is set up by the service provider to perform the tasks necessary to operate the unit No additional changes to these settings should be needed The control system also keeps track of diagnostic informat...

Страница 9: ...running in the normal state the unit displays this screen The unit powers up in an off condition To begin normal operation perform the steps in Table 1 Table 1 Step Action Procedure 1 Open the mercha...

Страница 10: ...machine is operational and the minimum throughput as described in Table 2 is not met on a per barrel basis product should be dispensed and discarded to increase throughput and help assure that product...

Страница 11: ...ere are up to five buttons that are activated on a screen to provide various functions using the control system Each button that is active has a label directly above it The label describes what the bu...

Страница 12: ...l to the scribe line on the faceplate as shown in Figure 6 3 When the barrel is full turn on refrigeration When refrigeration shuts off the product is ready to serve Relief Valve FCB Product Level FUB...

Страница 13: ...or from the BIB 2 Pull the connector sideways to disengage the line from the bag connector 3 Place a new BIB on the rack and open the cardboard flap Be careful not to puncture the bag with any sharp o...

Страница 14: ...t Minimum CO2 pressure to the Viper unit is 75 psig WATER Viper requires a minimum water flow rate of 100 gal per hr for a 2 barrel unit Minimum water pressure is 25 psig Maximum water pressure to the...

Страница 15: ...ambient temperature higher than 75oF the times may increase as the ambient temperatures increases Viscosity Setting The lowest possible viscosity settings are recommended to achieve desired drink qual...

Страница 16: ...y all external surfaces with a clean soft cloth Remove the drip tray if applicable and wash with a mild soap solution Dry the tray thoroughly and replace it CAUTION Do not use chlorine based solutions...

Страница 17: ...arrel Status menu A Sleep time set B Clock incorrectly set C No or incorrect wakeup time set A Check programming B Check programming C Check programming Barrel Status OFF A Not activated B Error has s...

Страница 18: ...low cap single compressor 100 gal per hr at 25psig min flowing pressure 25 p s i g min 90 p s i g 0 62 MPa max Ventilation Clearance Standard Condenser 2 on both sides or back 12 on top of the unit E...

Страница 19: ......

Страница 20: ...Cornelius Inc www cornelius com...

Отзывы: