![Cornelius Viper Elite Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cornelius/viper-elite/viper-elite_operators-manual_2668113013.webp)
Unit Connector
Bag Connector
(Red - Female)
(White - Male)
Syrup Tube
Operator’s Manual
© 2015-2017, Cornelius Inc.
- 9 -
Publication Number: 621360241LOEWOP
Figure 7.
T
YPE
2 BIB S
YRUP
C
ONNECTIONS
Refer to Table 7. and Figure 8. when replacing a Type 2 BIB container.
Table 7.
Step
Procedure
1.
Push in on the outer connector tab and pull the syrup hose and stub out to
unlock the connector from the BIB.
2.
Pull the connector sideways to disengage the line from the bag connector.
3.
Place a new BIB on the rack and open the cardboard flap. Be careful not to
puncture the bag with any sharp objects.
4.
Pull the bag connector out of the box and remove the dust cap.
5.
Rinse the QCD connector in warm water.
6.
Re-install the QCD connector onto the new BIB connector by slipping it onto
the connector and pushing the syrup hose and stub down toward the box.
Button should be flush, as shown in Figure 8.
Bag Connector
Stub
Syrup Tube
Connector Tab