1

 IMI CORNELIUS INC.  1996

August 13, 1996

TD243

IMI CORNELIUS INC.
One cornelius Place
Anoka, MN 55303-6234
Telephone (800) 238-3600
Facsimile (612) 422-3246

INSTALLATION MANUAL

FOR

VANGUARD 245 CHILLER

The Vanguard 245 Chiller is for chilling incoming water before it enters the beverage system. It is for use in high
ambient water conditions and high volume beverage locations where additional cooling is required. Pre-chilling
of the water improves the output of the beverage dispensing units.

The unit can sit on the floor or be mounted on the wall with the brackets as shown below. When mounting the
unit on the wall make sure air intake side is not facing the wall. The air exits the top. Make sure nothing is cov-
ering the top to ensure proper operation.

The separate 3-way water manifold should be attached to the 3 water inlets. Inlets 1 and 2 are for water to the
two carbonators on the back room panel or B-I-B stand, which has shut off valves on the panel. Inlet number 3
with a shut off valve and outlet number 3 is a separate circuit to supply chilled water to the ice machine (see
diagram).

The Vanguard 245 Chiller uses mechanical refrigeration in a water bath to chill the coils that the water passes
through.

Specifications

Width

24.5 

  (62  CM)

Height

31

 

(79 CM)

Depth

30

 

(76 CM)

Electrical

220V/50Hz  9.0 Amps or 115V/60Hz 15.0 Amp 20 Amp Circuit

Compressor

3/4 H.P.  Refrigerant 404a

Ice Bank

62 lbs. (28 Kgs.)

Shipping Weight

180 lbs. (82 Kgs.)

Operating Weight

245 lbs. (   Kgs.)

23

23

4

11 1/2

19

23

1. Two-inch angle iron, 3 pieces per bracket.

2. Drill 1/2

 holes, weld all pieces