 Installation and Service Manual

© 2004, IMI Cornelius Inc.

- 15 -

Publication Number: 710160089

UCC-40 PARTS LIST

Item

New Part No

Description

Old Part No.

Torrington Part 
No.

1

26-0064

Cabinet Ass’y

119-178-007

2

26-0146

Coil Ass’y - Freon

119-184-001

3

55-0339

Control - Temperature

155-969-000

186074001

4

23-0218

Plate - Compressor (1/3 hp)

119-066-004

5

35-0128

Power Cord (115v)

119-360-000

35-0124

Power Cord (220v)

115-558-000

6

55-0087

Condenser

101-434-000

7

23-0510

Shroud - Fan

115-194-000

8

35-0015

Blade - Fan

105-240-000

9

35-0094

Motor - Fan (115v)

119-646-000

35-0097

Motor - Fan (220v)

119-805-220

10

23-0302

Handle

119-118-000

11

23-0040

Bracket - Agitator Motor

115-659-000

(2 Required)

12

40-0411

Washer

106-141-000

13

35-0078

Motor - Agitator 115v

119-447-009

35-0079

Motor - Agitator 220v

119-447-229

14

23-0107

Bracket - Fan Motor

103-024-000

15

55-0031

Bushing

103-067-000

16a

26-0360

Compressor Ass’y 1/3hp 115v

35-0148

Relay 1/3 hp 115v

101-049-000

35-0104

Overload 1/3hp 115v

101-050-000

16b

26-0366

Compressor Ass’y
1/3hp 220v/50hz

35-0151

Relay 1/3hp 220v/50hz

119-803-001

35-0106

Overload 1/3hp 220v/50hz

119-803-002

16c

26-0362

Compressor Ass’y
1/3hp 220v/60hz

35-0152

Relay 1/3hp 220v/60hz

119-803-261

35-0107

Overload 1/3hp 220v/60 hz

119-803-262

17

23-0419

Lid Gray

119-165-007

18

26-0061

Bulb Holder

112-544-675

(Temperature Control)

23-0064

Bracket - Bulb Holder

119-791-097

19

26-0058

Blade - Agitator

115-790-001

20

40-0252

Pin - Cotter S.S.

106-140-000

21

40-0262

Plug - Cap

113-035-000

31699012

22

23-0130

Bracket - Line

119-185-707

23

55-0033

Bushing

119-426-875

34065

24

23-0208

Basket - Product Coil

119-192-001

25

65-0085

Tube - Vinyl

104-299-000

26

40-0019

Clamp

108-111-000

48114005

27

65-0047

Tube - Insulation 3/8 I.D.

104-249-000

28

40-0081

Connector S.S. 3/8 MPT x 3/8B

115-576-000

77081400

29

40-0243

Fitting - Compression

119-688-002

3/8 Tube x 3/8 MPT

30

55-0275

Pump S.S. 50 GPH

107-776-000

31

55-0215

Cover Insulation (Left)

115-396-000

32

55-0214

Cover Insulation (Right)

115-395-000

33

40-0249

Nut - Pack 3/8

119-689-000

34

40-0297

Screw

110-861-902

718400297

35

35-0035

Clamp V c/w Bolt

100-361-000

20543

36

35-0115

Pin - Hitch

101-046-002

37

35-0072

Motor 1/3hp 115v

115-442-000

60030058

35-0075

Motor 1/3hp 220v 50/60hz

115-442-220

71860673

38

40-0208

O Ring

103-123-000

31525012

39

26-0136

Coil Assembly CO2 Water

119-993-728

40

23-0231

Cover - Electrical Box

119-446-001

41

23-0819

Wrapper Electrical Box 115v

119-465-006

23-0783

Wrapper Electrical Box 220v

119-465-001

42

35-0062

Control - Liquid Level 115v

110-863-000

35-0065

Control - Liquid Level 220v 50/60hz

110-863-220

60439010

43

40-0288

Screw

103-462-000

Содержание UC-40

Страница 1: ...C 40 and UCC 40 Installation and Service Manual Release Date September 28 2004 Publication Number 710160089 Revision Date N A Revision N A Visit the IMI Cornelius web site at www cornelius com for all your Literature needs ...

Страница 2: ...is assumed that appropriate safety precautions are taken and that all local safety and construction requirements are being met in addition to the information contained in this manual To inquire about current revisions of this and other documentation or for assistance with any Cornelius product contact www cornelius com 800 238 3600 Trademarks and copyrights Aurora Cornelius Decade Hydro Boost Sitc...

Страница 3: ...ccessible for isolation of the equipment The equipment must be earth grounded Use and ELCB earth leakage circuit breaker GFCI ground fault interrupt for electrical power protection Use an HVAC circuit breaker to the power outlet circuit supplying the dispenser Each module or accessory requires a 120 VAC 15 Amp 60 HZ grounded outlet If 230 VAC 50 60 HZ use a minimum of 10 Amp outlet for each module...

Страница 4: ... DIMENSIONS See Illustration Below SHIPPING WEIGHT 135 lbs 61 4 kg OPERATING WEIGHT 241 lbs 109 5 kg ELECTRICAL RATING 115 VAC 60HZ 14 6 AMPS 220VAC 50 60HZ 7 3 AMPS Transformer Built In 24VAC Secondary REFRIGERATION 1 3 HP Lift Out Type Condenser Air Cooled Refrigerant R134a APPROVAL U L C S A N S F ...

Страница 5: ... electrical ratings shown on the dispenser nameplate amperage and voltage is recommended for satisfactory operation WATER SUPPLY DRAINAGE A water supply having a 1 2 O D 12 7mm copper water tube minimum is required with a minimum 20 PSIG 1 4 bar line pressure A shut off valve within three feet 1 meter of the unit is recommended A suitable water filter is recommended to ensure top quality drinks A ...

Страница 6: ...lets are 1 4 6 4mm barb fittings and are located at the front wall mid height of the dispenser Each syrup inlet in labeled with the valve number that it services If the syrup in lines need replacement or extension a 265 I D 6 7 mm I D polytube is recommended Avoid using soft or easily collapsible tubing on the syrup in lines Only stainless steel or plastic barb or compression type fittings should ...

Страница 7: ...on of the valve For diet type syrup the tank pressures should be set at from 3 to 8 psi 21 to 56 bar or as recommended by the syrup supplier Additional pressure may be necessary depending on the distance from the syrup tank to the unit 14 Mount the water filter assembly if used and water regulator in a convenient location 15 Connect water inlet line to water regulator set at 30 to 40 psig 2 1 to 2...

Страница 8: ...inutes to melt ice bank If ice remains repeat Steps 2 and 3 until all ice is melted Failure to melt all ice may cause the dispenser to freeze up after the new ice bank control is installed 4 Remove two screws from dispenser top and remove top 5 Remove old ice bank control 6 Install new ice bank control by pushing probe down into the 3 4 tube until it stops on the bottom of the tube Secure probe wi...

Страница 9: ...ter Bath Maintenance It will be necessary to periodically check and correct the water level of the water bath The frequency of filling will depend on the environment within which the dispenser is operating and consequently the degree of evaporation of water Noisy operation and or reduced cooling capacity can be caused by insufficient water in the water bath The condenser coil will require periodic...

Страница 10: ...n flush the cleaning solution from the lines with clean water by connecting a pressurized figal with clean water Pressurized and flush the valves by pulsing the valve for 15 cycles and then flushing three 3 minutes as described in the previous paragraph Continue pulsing and flushing until testing with phenolphthalein shows the rinse water is free of residual detergent 5 Sanitize each valve product...

Страница 11: ... drip tray and position the tube to drain into the drain pan 2 After the ice has melted remove the deck 3 Thoroughly clean around all the coils and between all crevasses with a brush and cleaning solution to remove all algae and foreign matter Dry the water bath 4 Clean the condenser with a vacuum cleaner or a soft bristle brush 5 Clean compressor agitator motor and fan assembly with a cloth wipin...

Страница 12: ...NG The L L C with timer will give no protection against the initial startup of a new carbonator pump with no water being present at the pump A new pump which has never pumped water is considered dry and will suffer damage in a matter of 2 to 3 minutes FEATURES 220v 50z and 115v 60z models are available 3 minute and 7 minute models are available Designed to control and protect a 1 2hp maximum pump ...

Страница 13: ...Installation and Service Manual 2004 IMI Cornelius Inc 11 Publication Number 710160089 WIRING DIAGRAM 60439011 230V 50HZ 60439010 115V 60HZ 60439013 230V 50Z 60439012 115V 60Z ...

Страница 14: ...Installation and Service Manual Publication Number 710160089 12 2004 IMI Cornelius Inc FLUIDS GAS DIAGRAM ...

Страница 15: ...Installation and Service Manual 2004 IMI Cornelius Inc 13 Publication Number 710160089 WIRING DIAGRAM UCC 40 WIRING DIAGRAM ...

Страница 16: ...Installation and Service Manual Publication Number 710160089 14 2004 IMI Cornelius Inc UCC 40 PARTS EXPLODED DIAGRAM ...

Страница 17: ...7 Overload 1 3hp 220v 60 hz 119 803 262 17 23 0419 Lid Gray 119 165 007 18 26 0061 Bulb Holder 112 544 675 Temperature Control 23 0064 Bracket Bulb Holder 119 791 097 19 26 0058 Blade Agitator 115 790 001 20 40 0252 Pin Cotter S S 106 140 000 21 40 0262 Plug Cap 113 035 000 31699012 22 23 0130 Bracket Line 119 185 707 23 55 0033 Bushing 119 426 875 34065 24 23 0208 Basket Product Coil 119 192 001 ...

Страница 18: ...934 000 70 55 0276 Pump Brass 125 GPH 110 872 000 71 26 0421 Electrode Assembly 19 119 915 019 72 40 0116 Elbow S S 1 4B X 1 4 Swivel Nut 112 708 000 77040100 73 40 0016 Clamp 105 039 000 48114003 74 65 0003 Tube Braid 115 115 000 174478000 75 40 0409 Washer 1 4 Flare 104 053 000 30359 76 26 0038 Back Check Single 113 139 000 65259001 77 40 0065 Connector S S 1 4B X 1 4B 100 826 000 77040200 78 40...

Страница 19: ...IMI Cornelius Inc www cornelius com ...

Отзывы: