Olympus Post-Mix Service Manual
© 2002, IMI Cornelius Inc.
- 9 -
Publication Number: 750300229
3. Connect optional drip tray drain hose (if used). Be sure to drill out the stem in the drip pan if a drain
hose is used (use a 11mm (7/16”) bit).
4. Reinstall drip tray and position water bath overflow hose in drip tray indent.
Primary And Secondary CO
2
Regulator Settings
1. Open CO
2
cylinder valve slightly to allow lines to slowly fill with gas. When lines are fully pressurized
open the valve all the way until it back-seats itself (this prevents leaks from the valve).
2. Adjust the cylinder CO
2
regulator to 5.2 bar (75 psig) for bag-in-box applications, 2.8 bar (40 psig) for
sugar base tank applications and .69 bar (10 psig) for diet base tank applications.
NOTE: The Olympus™ dispenser with integral cold carbonator requires CO
2
supply pressure of
5.2 bar (75 psig).
3. Bleed air from the lines with the carbonator tank relief valve.
4. Check the system for gas leaks.
Connect Electrical Power
NOTE: Before connecting electrical power to the dispenser, refer to nameplate to verify the power
requirements.
1. Make sure that the electrical power circuit breaker is switched off or the fuse removed.
2. Plug the dispenser into the power receptacle.
3. Reinstall wires to On/Off and key lock switches. Rest panel on top of unit.(ON/OFF switch optional on
small unit)
4. Turn electrical power on. Turn On/Off and key lock switches ON.(ON/OFF switch optional on small
unit)
Check for Leaks
1. Bleed air from the lines by activating dispensing valves.
Connect optional
drip tray drain
hose
Position water
bath overflow
hose in drip
tray indent