CAUTION
— Make sure that the power to the dispenser is disconnected (unplugged) before
removing the covers.
5. Remove access cover and fill the water bath with water until it comes out the overflow tube. Make
sure the overflow tube is not blocked or plugged. Use low-mineral tap water, not distilled or deionized
water.
CAUTION
— Never add antifreeze or other chemicals to the water bath as serious damage may
occur.
Connect Syrup, Water, CO
2
and Carbonated Water Lines
Routing And Connecting Lines
1. Route syrup and plain water lines underneath the dispenser. The lines can be routed up through a
hole in the counter or from the back of the unit. Connect the inlet lines to the appropriate inlet connec-
tions. The water inlet requires two connections, one directly to the carbonator pump inlet and one to
the pump bypass inlet fitting behind the splash panel (see plumbing diagram). Be sure to connect the
water supply to both inlet connection points.
Disconnect
wires from
ON/OFF and
key lock
switches (ON/
OFF switch
optional on
small unit)
Remove
front mer-
chandiser
and top
vented
panel
Fill water
bath through
hole in top
Access
Syrup inlets
Water bath
overflow
Carbonator pump
bypass water inlet
check valve
Water inlet line to
carbonator pump