![Cornelius Quantum 1000 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/cornelius/quantum-1000/quantum-1000_service-manual_2668248006.webp)
Continuous Flow Icemaker Service Manual
© 2004-2011, IMI Cornelius Inc.
- 3 -
Publication Number: 630460174SER
GENERAL DESCRIPTION
This section gives the Unit description, theory of operation, and design data for continuous flow icemaker series
500, 700, 1000, and 2000.
S
PECIFICATION
C
HART
NOTE: For units not listed in above chart, refer to nameplate or contact factory service.
Models
Condensing
Unit
VAC
HZ
PH Wire
Comp.
RLA
Fan
Amps
GRMT
R
Amps
Refrigerant
Circuit
Fuse
Oz.
Type
WCC500-A
Air Cooled
115
60
1
2
10.1
1.1
2
24
R404A
20
WCC500-W
Water Cooled
115
60
1
2
10.1
N/A
2
11
R404A
20
WCC502-A
Air Cooled
220/240
50
1
2
5.3
0.5
1.6
24
R404A
20
WCC502-W
Water Cooled
220/240
50
1
2
5.3
N/A
1.6
11
R404A
20
WCF510-A
Air Cooled
115
60
1
2
10.1
1.1
2
24
R404A
20
WCF510-W
Water Cooled
115
60
1
2
10.1
N/A
2
11
R404A
20
WCF512-A
Air Cooled
220/240
50
1
2
5.3
0.5
1.6
24
R404A
20
WCF512-W
Water Cooled
220/240
50
1
2
5.3
N/A
1.6
11
R404A
20
WCC700-A
Air Cooled
115
60
1
2
14.6
1.6
2
17.5
R404A
20
WCC700-W
Water Cooled
115
60
1
2
12
N/A
2
13
R404A
20
WCC701-A
Air Cooled
208/230
60
1
2
7.7
1.6
2
24
R404A
20
WCC701-W
Water Cooled
208/230
60
1
2
7.7
N/A
2
13
R404A
20
WCC702-A
Air Cooled
220/240
50
1
2
8.2
0.5
1.6
24
R404A
20
WCC702-W
Water Cooled
220/240
50
1
2
8.2
N/A
1.6
13
R404A
20
WCF710-A
Air Cooled
115
60
1
2
14.6
1.6
2
17.5
R404A
20
WCF710-W
Water Cooled
115
60
1
2
12
N/A
2
13
R404A
20
WCC711-A
Air Cooled
208/230
60
1
2
7.7
1.6
2
24
R404A
20
WCC711-W
Water Cooled
208/230
60
1
2
7.7
N/A
2
13
R404A
20
WCF712-A
Air Cooled
220/240
50
1
2
8.2
0.5
1.6
24
R404A
20
WCF712-W
Water Cooled
220/240
50
1
2
8.2
N/A
1.6
13
R404A
20
WCC1001-A
Air Cooled
208/230
60
1
2
7.5
0.85
2
26
R404A
20
WCC1001-W
Water Cooled
208/230
60
1
2
7.5
N/A
2
17
R404A
20
WCC1002-A
Air Cooled
220/240
50
1
2
8.9
0.85
2
26
R404A
20
WCF1101-A
Air Cooled
208/230
60
1
2
7.5
0.85
2
26
R404A
20
WCF1101-W
Water Cooled
208/230
60
1
2
7.5
N/A
2
17
R404A
20
WCF1102-A
Air Cooled
220/240
50
1
2
8.9
0.85
2
26
R404A
20
WCC1001-R
Remote
220/240
60
1
2
7.5
N/A
2
120
R404A
15
WCF1101-R
Remote
208/230
60
1
2
7.5
N/A
2
120
R404A
15
WCC2001–A
Air–Cooled
208/230 60
1
2
12.9
.85
(2)
2
46
R404A
25
WCC2001–R
Remote
208/230
60
1
2
12.9
1.7
(2) 2
220
R404A
25
WCC2001–W
Water Cooled
208/230
60
1
2
12.9
N/A
(2) 2
28
R404A
25
WCC2002–A
Air Cooled
220/240
50
1
2
11.4
.85
(2) 2
46
R404A
25
WCF2201–A
Air–Cooled
208/230
60
1
2
12.9
.85
(2) 2
46
R404A
25
WCF2201–W
Water Cooled
208/230
60
1
2
12.9
N/A
(2) 2
28
R404A
25
WCF2202–A
Air Cooled
220/240
50
1
2
11.4
.85
(2) 2
46
R404A
25
400
380
360
340
320
300
280
260
240
650
600
550
500
450
400
350
1100
1000
900
800
700
600
Capacity
Lbs./24 hr
.
Capacity Lbs./24 hr
.
Capacity Lbs./24 hr
.
90
80
70
60
50
90
80
70
60
50
90
80
70
60
50
–50
–70
–90
–100
Water Temperature Deg. F
Water Temperature Deg. F
Water Temperature Deg. F
Air Temperature Deg. F
Air Temperature Deg. F
Air Temperature Deg. F
–50
–70
–90
–100
–50
–70
–90
–100
WCC500
WCC700
WCC1000
Содержание Quantum 1000
Страница 27: ......
Страница 28: ...IMI Cornelius Inc www cornelius com...