Continuous Flow Icemaker Service Manual
© 2004-2011, IMI Cornelius Inc.
- 21 -
Publication Number: 630460174SER
C
APACITOR
C
HECK
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
S
AFETY
C
ONTROLS
Your icemaker unit has several safety and control devices incorporated into its design.
!
WARNING:
None of the below described devices should ever be “bypassed” to allow the unit to function.
Failure to comply could result in serious injury, death or damage to the equipment.
The safety and control system shut–off devices are:
1. Low water shut off reed switch located in icemaker float assembly. (Automatic reset type.)
2. Gearmotor thermal overload, manual reset type (red button on motor).
3. Compressor thermal overload, automatic reset type.
4. Anti–freeze relay and associated circuit. See wiring diagrams.
5. Main service switch located on top of the control box.
6. Bin Control.
7. High pressure cut out (water cooled only).
1. Check or replace start capacitor, disconnect bleed
resistor before checking for shorted capacitor.
2. Check or replace run capacitor (if supplied) check for
shorted capacitor or either terminal grounded to
case.
Figure 20. Gear Motor Overload
GEAR MOTOR OVERLAY