![Cornelius MILLENNIUM MJ30-4 PB Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/cornelius/millennium-mj30-4-pb/millennium-mj30-4-pb_installation-and-service-manual_2667883018.webp)
Troubleshooting Guide
17
Problem
Probable Cause
Remedy
UNIT IS DISPENSING
CONCENTRATE ONLY
REFRIGERATION SYSTEM
HAS BEEN RUNNING FOR
EXTENDED PERIOD
WITHOUT SHUTTING OFF
FROZEN WATER COIL.
Compressor not cycling off.
Check the ice bank control. Be sure
that the control has not overheated
and fused the contacts together.
Replace as required.