Troubleshooting Guide
15
Problem
Probable Cause
Remedy
TWO OR MORE PUMPS
OPERATE WHEN ONLY
ONE BUTTON IS PUSHED.
(Cont.)
VRB Board mounting screw
insulator is missing or
improperly installed.
Check the corresponding VRB board
to the valve that is dispensing in
error. Where the screw mounts the
transistor to the bracket, be sure that
the spacer bushing is present and the
screw is not over tightened. Screw
contact with the bracket will cause a
short and the firing of the valve when
other valves are energized.
WITH POWER PRESENT
DISPENSER WILL NOT
COOL
Drink temperature should be
35-45
°
F
2-7
°
C
Refrigeration shut off switch
is in the off position.
Depleted ice bank (not
applicable after period of
heavy usage.)
Refrigeration shut off switch is
located on the top of the dispenser.
This switch will disable the
compressor and condenser fan motor.
Be sure the switch is in the on
position.
Remove rear bonnet covering the
refrigeration deck. CAUTION should
be observed when working in this
area as the dispenser is energized and
operational. Check to see if the
compressor is running . If so allow
the system to recover (approximately
1 hour).
WITH POWER PRESENT
COMPRESSOR WILL NOT
RUN.
(Compressor shell is cold to
touch.)
Loose or broken wire
connections.
Defective compressor start
component.
Ice bank control not connected
or defective.
Check the wire connections at the
compressor. Be sure they are tightly
secured.
Check the compressor start relay.
Replace as required.
Check the ice bank control
connections. To test, place jumper
between the 2 leads. If the
compressor starts ,the ice bank
control is defective.
COMPRESSOR RUNS BUT
NO COOLING IS TAKING
PLACE.
Low refrigerant charge.
Refrigerant restriction.
Contact a refrigeration service
technician. They will check for leaks
(sign of oil at joints and fitting) and
will recharge if necessary.
Refrigeration technician will examine
the system for, kinks in lines,
restrictions, etc. Heat exchanger may
need to be replaced.
Содержание MILLENNIUM MJ30-4 PB
Страница 19: ...Millennium 4 Valve Schematic 18 ...
Страница 22: ...Final Assembly 21 ...
Страница 28: ...Valve Block Assembly P N 45045 27 ...
Страница 31: ...PORTION CONTROL ASSEMBLY 30 ...
Страница 32: ...PORTION CONTROL ELECTRICAL DIAGRAM P N 720201800 31 ...
Страница 58: ...Notes ...
Страница 59: ...P N85318 Rev B Print Date 2 99 ...