FCB Cord Kit for V-Series 4 Flavor Installation Instructions
© 2003-2014, Cornelius Inc.
- 1 -
Publication Number: 629088373INS
INSTALLATION INSTRUCTIONS
FCB C
ORD
K
IT
FOR
V-S
ERIES
4 F
LAVOR
The following instructions should be used for installation of a power cord for a V-Series 4 Flavor unit.
Each kit will supply power to 1 unit.
Parts List
Tools Required
Phillips Screwdriver
Flat Screwdriver
Pliers
CAUTION
– Only trained and certified electrical technicians should service this unit. ALL WIRING
MUST CONFORM TO NATIONAL AND LOCAL CODES.
DANGER
– To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must
be installed in the electrical circuit of all units.
WARNING
– To avoid possible electrical shock make sure the unit is properly grounded by con-
necting the earth ground cable, in the power cord to any connection in the machine marked with a
ground symbol.
CAUTION
– The wiring must be properly grounded and connected through a disconnect switch
(slow-blow fuse or equivalent HVAC/R circuit breaker).
Electrical Requirements
Refer to the nameplate to determine the power requirements before connecting electrical power to the
unit. Voltage across contactor terminals L1 and L2, with the compressor running, must be within voltage
limits described in Table 1.
If the line voltage does not meet these requirements see the possible corrective actions in Table 2.
Item
Number
Description
Qty
1
50 Amp Power Cord
1
2
Strain Relief
2
Table 1
Unit
Requirements
V-Series 4 Flavor Integral Condense
208-230V, 60Hz, 50 Amp
V-Series 4 Flavor Water Condense
208-230V, 60Hz, 50 Amp
Table 2
Voltage
Corrective Action
Below 180 VAC
Do Not Connect Unit
180-190 VAC
Boost voltage by +32 V
191-207 VAC
Boost voltage by +16 V
208-230 VAC
Use line voltage
231-246 VAC
Reduce voltage by –16 V
247-262 VAC
Reduce voltage by –32 V
Above 262 VAC
Do Not Connect Unit