FCB Cord Kit for V-Series 4 Flavor Installation Instructions
Publication Number: 629088373INS
- 2 -
© 2003-2014, Cornelius Inc.
Installation Steps
1.
Switch the power to the unit off or remove the fuse to the electrical power circuit breaker.
2.
Remove the back panel and the right side panel to gain access to the electrical area in the back of
the unit.
3.
Remove the cover of the contactor box.
4.
On both strain relief parts, loosen the screws until no threads show through the bottom.
5.
Install the first strain relief to the bottom of the unit.
6.
Install the second strain relief to the side of the con-
tactor box.
7.
Feed the power cord through the first strain relief,
lead end first, from the outside of the unit to the
inside of the unit.
8.
Pull the power cord to the second strain relief.