Cornelius DPC 230 Скачать руководство пользователя страница 12

161952801

10

Ice Portion Size Adjustment.

Located in the rear of the electrical box assembly, you will find the ICE PORTION SIZE ADJUSTMENT 
KNOB. Turn the ICE PORTION SIZE ADJUSTMENT KNOB to the left (counterclockwise) for less ice  
dispensed or turn the knob to the right (clockwise) for more ice dispensed.

Adjust the ice portion size as instructed in this paragraph.

 Time Delay Between Dispensed Ice Portions Adjustment.

Inside the electrical control box assembly, you will find a time delay between dispensed ice portions TIME
DELAY ADJUSTMENT SCREW (blue plastic square box with screw driver slot in center) on the portion control
board. The time delay between dispensed ice portions may be adjusted from between 0 and 60-seconds. Turn
the TIME DELAY ADJUSTMENT SCREW for more or less time between dispensed ice portions as indicated by
adjustment marks on the control board next to the blue plastic square box. This makes it inconvenient to fill the
ice chest from the dispenser.

Adjust the time delay between ice portions as instructed in this paragraph.

OPERATION

NOTE: If the dispenser has not vended ice for two hours, an automatic agitation cycle will be initiated
by the solid-state portion control and will last approximately two seconds to stir up the ice in the ice
bin hopper.

1. Referring to ELECTRICAL REQUIREMENTS, connect electrical power to the dispenser.

Manual Dispense Dispenser.

With the MANUAL/PORTION CONTROL SWITCH placed in the “MANUAL” position,  pressing the Ice Dis-
pense Switch on the electrical  box assembly front panel will activate the dispenser and ice will be dispensed
continuously until the switch is released. If the  MANUAL/PORTION CONTROL SWITCH is placed in the “POR-
TION” position, a set time of approximately 1/2 to  20-seconds (adjustable) will be established and pressing the
Ice Dispense Switch will dispense that pre-set portion of ice.

Key Operated Dispensers.

A special key must be used to activate the dispenser to dispense ice. With the MANUAL/PORTION CONTROL
SWITCH placed in the “MANUAL” position, activating the dispenser key switch on the electrical control box front
panel  will dispense ice continuously until the key switch is released. If the  MANUAL/PORTION CONTROL
SWITCH is placed in the “PORTION” position, a set time of approximately 1/2 to  20-seconds (adjustable) will
be established and activating the dispenser key switch will dispense that pre-set portion of ice.

Card Operated Dispenser.

A special plastic card must be used to activate the dispenser to dispense ice. With the MANUAL/PORTION
CONTROL SWITCH placed in the “MANUAL” position, activating the dispenser with the special plastic card will
dispense ice continuously until the card is removed. If the  MANUAL/PORTION CONTROL SWITCH is placed
in the “PORTION” position, a set time of approximately 1/2 to  20-seconds (adjustable) will be established and
activating the dispenser with the special plastic card will dispense that pre-set portion of ice.

Содержание DPC 230

Страница 1: ...ICE DISPENSER PRINTED IN U S A IMI CORNELIUS INC 1995 Part No 161952801 January 1995 Revised 9 11 97 THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before install...

Страница 2: ...NSTALLATION 7 INSTALLING ICE DISPENSER 7 FILLING DISPENSER ICE BIN HOPPER WITH ICE 8 ADJUSTMENTS 8 OPERATION 10 MAINTENANCE 13 CLEANING AND SANITIZING 13 DAILY CLEANING SEE FIGURE 2 13 CLEANING AND SA...

Страница 3: ...or WARNING are typically near specific hazards WARNING General precautions are listed on CAUTION safety signs CAUTION also calls attention to safety mes sages in this manual CAUTION Follow Safety Inst...

Страница 4: ...2 161952801 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 5: ...rvice Person and the User have been given special attention in the development and engineering of our Ice Dispensers If you encounter a problem which is not covered in this manual please feel free to...

Страница 6: ...161952801 4 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 7: ...but will gladly render assistance necessary to pursue your claim Merchandise must be inspected for concealed dam age within 15 days of receipt WARRANTY REFERENCE INFORMATION Warranty Registration Date...

Страница 8: ...hase 120 VAC 60 HZ Plumbing Connections Bin Drain 1 inch O D Vinyl Tube 11 06 24 6 9 54 30 30 41 13 5 15 12 11 25 9 56 FRONT VIEW SIDE VIEW REAR VIEW A CONDENSATE DRAIN 1 2 F P T B BIN AND STATION DRA...

Страница 9: ...move the skid NOTE The leg kit loose shipped and found inside the Ice Dispenser must be installed at this time 3 Install the four legs in four corners of the Ice Dispenser base as shown in Figure 2 4...

Страница 10: ...w ice to sit at room temperature for approximately 1 2 hour before placing ice in the ice bin hopper Ice to be used to fill the ice bin hopper must be in the form of small cubes chunklets or cracked i...

Страница 11: ...161952801 9 TOP COVER STATION TUB GRILLE LEG 4 ELECTRICAL BOX ASS Y FRONT PANEL FIGURE 2 DISPENSER COMPONENTS PUSH BUTTON MODEL SHOWN...

Страница 12: ...l Dispense Dispenser With the MANUAL PORTION CONTROL SWITCH placed in the MANUAL position pressing the Ice Dis pense Switch on the electrical box assembly front panel will activate the dispenser and i...

Страница 13: ...H placed in the MANUAL position activating the dispenser with the special token will dispense ice If the MANUAL PORTION CONTROL SWITCH SWITCH is placed in the PORTION position a set time of approximat...

Страница 14: ...161952801 12 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 15: ...90 days following Sanitizer Manufacturer s recommendations Use Chlor Tergent Oakite Products Inc or an equivalent sanitizer CAUTION DO NOT USE CHLORINE CLEANSING POWDERS FOR CLEANING Use of chlorine...

Страница 16: ...ponge and water detergent soap solution Rinse out sponge with clean water then wring excess water out of the sponge and wipe off all external surfaces of the dispenser Wipe dispenser dry with a clean...

Страница 17: ...01 15 115V 15 AMP 60HZ POWER SUPPLY PROVIDED BY INSTALLER MACHINE OUTLET BOX GREEN COLORED GROUND SCREW INSIDE BOX BLACK WHITE GROUND WIRE WHITE BLACK WHITE BLACK MACHINE CONTROL BOX FIGURE 3 WIRING D...

Страница 18: ...161952801 16 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 19: ...loose C No electrical power to the dispenser C Restore electrical power to the dispenser D Ice dispense switch inoperative D Call a qualified Service Person E Inoperative ice rotator motor E Call a q...

Страница 20: ...161952801 18 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 21: ...161952801 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 10 11 30 31 32 33 37 FIGURE 4 ICE DISPENSER...

Страница 22: ...69189 004 Tube 75 I D By 24 In Long 169189 004 Tube 75 I D By 40 In Long 11 169225 017 Insulation Tube 88 I D By 6 In Long 169225 017 Insulation Tube 88 I D By 22 In Long 169225 017 Insulation Tube 88...

Страница 23: ...r Lock 36 161009 Machine Screw Knurled No 10 32 By 1 2 In Long 37 08387 Machine Screw Phil Truss Hd No 10 32 By 1 2 In Long 38 167305 001 Sheet Metal Screw Sl Hex Hd No 14 By 5 8 In Long 39 38220 Mach...

Страница 24: ...K BR BR VEND AUX AUX COM MAIN PORT YL BK BL SAFTY SWITCH RD RD OR NET LI GER MTR POT OR OR YL BK RD BL GR YL RD WH BK BK BR BR BK YL BL VEND POT AUX AUX COM MAIN PORT SAFTY SWITCH BR NET LI GER MTR OR...

Страница 25: ...42570 Conduit Motor 14 42571 Conduit Power 15 42572 Box Electrical 16 42579 Cover Electrical Box Not Shown 17 09939 Knob Selector Switch 18 43454 Insulation Barrier 19 01834 Button Plug Push Button Ke...

Страница 26: ...ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D...

Страница 27: ...C CORPORATE HEADQUARTERS One Cornelius Place Anoka Minnesota 55303 6234 763 421 6120 800 238 3600 Distributed By Commercial Refrigeration Service Inc WWW IceCubes NET WWW CorneliusParts COM 866 423 62...

Отзывы: