Cornelius COR9530UBCST Скачать руководство пользователя страница 18

 COR9530UBCST Service Manual

Publication Number: 630460279SER

- 14 -

© 2004, IMI Cornelius Inc.

P

RINCIPALES

 P

ROBLEMAS

 

DEL

 R

EFRIGERADOR

Posibles causas y soluciones

PROBLEMA

POSIBLE CAUSA

SOLUCION

COMPRESOR NO ARRANCA

NO HAY VOLTAJE EN LA 
TOMA DE ALIMENTACION

VERIFIQUE CON UN 
VOLTIMETRO

CONDUCTO ELECTRICO O 
ALAMBRES CORTADOS

UTILIZANDO UN 
OHMIMETRO, VERIFIQUE SI 
EXISTE CONTINUIDAD EN EL 
CONDUCTOR ELECTRICO O 
ALAMBRE

FALLA EN LOS 
COMPONENTES 
ELECTRICOS TALES COMO: 
TERMOSTATO, PROTECTOR 
TERMICO

REEMPLAZAR EL 
COMPONENTE 
DEFECTUOSO

TERMOSTATO EN POSICION 
"OFF"

FIJE LA POSICION DE LA 
PERILLA DEL TERMOSTATO 
EN FRIO MAXIMO Y 
OBSERVE SI EL 
COMPRESOR ARRANCA

BOBINAS DEL MOTOR DE 
COMPRESOR CORTADAS O 
QUEMADAS

MIDA LA RESISTENCIA 
OHMICA DE LAS BOBINAS 
PRINCIPAL Y AUXILIAR 
UTILIZANDO UN 
OHMIMETRO Y 
COMPARELAS CON LOS 
VALORES CORRECTOS 

CONDENSADOR SUCIO, 
FALTA CIRCULACION DE 
AIRE

LIMPIE EL CONDENSADOR Y 
PERMITA LA CIRCULACION 
DE AIRE

BAJO VOLTAJE

PARA ELIMINAR EL 
PROBLEMA DE VOLTAJE 
MENOR QUE 103 VOLTS, ES 
RECOMENDABLE EL USO DE 
UN REGULADOR DE 
VOLTAJE

COMPRESOR TRANCADO

REEMPLACE EL 
COMPRESOR

DEMASIADO FRIO

TERMOSTATO FIJADO EN 
POSICION MUY FRIA

FIJE LA PERILLA DEL 
TERMOSTATO A UNA 
POSICION MAS CALIENTE Y 
VERIFIQUE SI EL 
COMPRESOR PARA 
DENTRO DEL RANGO DE 
OPERACION DEL 
TERMOSTATO

TERMOSTATO NO 
DESCONECTA LA UNIDAD 
CONDENSADORA

VERIFIQUE LA FIJACION DEL 
BULBO DEL TERMOSTATO, 
SI EL PROBLEMA 
CONTINUA, CAMBIE EL 
TERMOSTATO

Содержание COR9530UBCST

Страница 1: ...LE COOLERS COR9530UBCST Service Manual Release Date May 2004 Publication Number 630460279SER Revision Date NA Revision A Visit the IMI Cornelius web site at www cornelius com for all your Literature n...

Страница 2: ...d that appropriate safety precautions are taken and that all local safety and construction requirements are being met in addition to the information contained in this manual To inquire about current r...

Страница 3: ...lectrical Wiring 4 Cleaning and Preventive Maintenance 5 Condensate Disposal System 5 Troubleshooting 6 Possible causes and solutions 6 Espa ol 9 Caracteristicas del equipo 9 Sistema de Refrigeracion...

Страница 4: ...COR9530UBCST Service Manual Publication Number 630460279SER ii 2004 IMI Cornelius Inc...

Страница 5: ...attached to one side of the compressor s box In any given situation if the compressor overheats or the voltage source varies drastically the thermal protector opens turning off the compressor After t...

Страница 6: ...ling cabinet It also starts the compressor motor whenever the cabinet rises above the desired temperature The temperature control consists of a switch which is mechanically activated by a diaphragm Th...

Страница 7: ...s discharged into the evaporator 6 The evaporator s serpentine allows the refrigerant to absorb and remove heat from the cooling compartment 7 The drop in temperature inside the cooling compartment is...

Страница 8: ...COR9530UBCST Service Manual Publication Number 630460279SER 4 2004 IMI Cornelius Inc ELECTRICAL WIRING FIGURE 3...

Страница 9: ...required Check it regularly for excessive water accumulation 6 Replace any malfunctioning parts as soon as possible Ask your dealer or service agency to order the parts required 7 It is most importan...

Страница 10: ...condenser and allow for air circulation Low voltage Use a voltage regulator if the voltage is lower than 103 volts Compressor is stuck Change the compressor THE TEMPERATURE IS TOO COLD Thermostat kno...

Страница 11: ...or electrical components are in direct contact with metallic parts Check for appropriate insulation on the connections of each electrical component NOISE The refrigerator is not properly leveled Chec...

Страница 12: ...st the door hinges if needed replace the gasket if broken The refrigerator has been placed at an inadequate location The unit must not be near sources that produce too much heat NO ILLUMINATION The li...

Страница 13: ...protector t rmico es un dispositivo termosensible montado en el costado de la caja del compresor Si el motor del compresor se pone demasiado caliente o toma una cantidad excesiva de corriente el prote...

Страница 14: ...nt n del evaporador Esto crea una baja presi n que causa que el refrigerante se vaporice y absorba calor seg n pasa a trav s del evaporador Filtro El filtro est localizado en el conducto del refrigera...

Страница 15: ...mi ndolo y forz ndolo en el serpent n del condensador 4 El condensador ayudado por el motor del ventilador del condensador desplaza calor del refrigerante seg n fluye a trav s del serpent n del conden...

Страница 16: ...COR9530UBCST Service Manual Publication Number 630460279SER 12 2004 IMI Cornelius Inc DIAGRAMA EL CTRICO FIGURE 7...

Страница 17: ...ea requerido Rev sela regularmente para prevenir una acumulaci n excesiva de agua 6 Reemplace cualquier pieza o parte defectuosa tan pronto sea posible Dir jase a su distribuidor o agencia de servicio...

Страница 18: ...MO Y OBSERVE SI EL COMPRESOR ARRANCA BOBINAS DEL MOTOR DE COMPRESOR CORTADAS O QUEMADAS MIDA LA RESISTENCIA OHMICA DE LAS BOBINAS PRINCIPAL Y AUXILIAR UTILIZANDO UN OHMIMETRO Y COMPARELAS CON LOS VALO...

Страница 19: ...AS PARRILLAS NO DEBEN DE CUBRIRSE CON NINGUN PLASTICO O MATERIAL QUE OBSTRUYA LA CIRCULACION DEL AIRE DENTRO DEL REFRIGERADOR REFRIGERADOR CON SOBRECARGA DE GAS VERIFIQUE SI EXISTE CONDENSACION O FORM...

Страница 20: ...ACTO CON METAL TENIENDO EL COMPRESOR FUNCIONANDO VERIFIQUE SI PARTES METALICAS ESTAN EN CONTACTO Y O QUE LOS TORNILLOS DE SUJECCION DEL CONDENSSADOR ESTEN DEBIDAMENTE APRETADOS ABANICO DEL EVAPORADOR...

Страница 21: ...AJUSTADA O SI EL EMPAQUE ESTA ROTO AJUSTE LA PUERTA O REEMPLACE EL EMPAQUE EL REFRIGERADOR ESTA MAL UBICADO EL REFRIGERADOR NO DEBE DE ESTAR UBICADO CERCA DE FUENTES DE CALOR LAMPARA NO ENCIENDE SWIT...

Страница 22: ...COR9530UBCST Service Manual Publication Number 630460279SER 18 2004 IMI Cornelius Inc...

Отзывы: