After the legs are installed, level the cabinet by using the adjustable portion of the legs as needed. This is
very important to insure proper draining and door operation.
To install casters
Casters are supplied as optional equipment. To install the casters, follow the directions for installing legs .
I
NSTALL
THE
C
ONDENSATE
D
ISPOSAL
S
YSTEM
WARNING
- The condensate disposal system is designed to dispose of the water from the
evaporator only under normal operating conditions. When cases are used with ice or when
additional water is generated by the case through abnormal usage or ambient conditions, a floor
drain or similar arrangement might be required.
Top mounted units
Depending on the model ordered, an electric condensate evaporator pan is available to dispose of
condensate water. The electric evaporator pan plugs into a 115 V 15 AMP line which should be a
separate line from the cabinet power supply.
FIGURE 4
FIGURE 5
Sealant