Environmental Requirements

I

NITIAL

 I

NSTALLATION

 P

ROCEDURE

Delivery Inspection and Unpacking

I

NSPECTION

Upon delivery inspect the brewer for damage or irregularities and immedi-
ately report problems to the delivering carrier and file a claim with that car-
rier.

1. Open loose parts packages and inspect parts.

2. Make sure all items are present.

CAUTION: This unit is designed for indoor installation 

only, in a non-harsh environment, and out of direct sunlight.

CAUTION: If the unit is exposed to freezing temperature 

water in the unit will freeze and may damage the unit.

LOOSE PARTS:

LBIT Double

Name

Part Number

Quantity

Urn Filling Tube

560005292

1

3/4” X 1/2” Barb Fitting

560005289

1

Install Instructions - English

630460160

1

Install Instructions - Spanish

630460161

1

Quick Reference Guide - English

630406152

1

Quick Reference Guide - Spanish

630460153

1

Sanitizing Instructions - English

630460165

1

Sanitizing Instructions - Spanish

630460175

1

Drip Tray

560005866

1

Cup Rest

560005867

2

1/2” Union Fitting

560005721

1

Rinse Pitcher

560005277

2

Содержание Brewed Iced Tea

Страница 1: ...ipton Brewed Iced Tea Double Valve Dispenser Training Installation Service Manual Safety Specifications Installation Service Training Part No 630460171 May 7 2002 2001 2002 IMI Cornelius Inc Revision...

Страница 2: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 ii May 7 2002...

Страница 3: ...on this manual pro vides Cornelius expects proper installation that includes taking appropriate safety precau tions as well as adhering and meeting all local safety and construction requirements To in...

Страница 4: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 iv May 7 2002...

Страница 5: ...Cleaning and Sanitation Practices 5 SYSTEM OVERVIEW 7 Theory of Operation 7 Function Keys 7 Language key 7 Menu key 7 Stop key 7 Rinse key 8 Run key 8 Menus and Modes of Operation 8 DATA VIEW mode 8 S...

Страница 6: ...lation Procedure 18 Delivery Inspection and Unpacking 18 Inspection 18 Installation Procedure 19 LBIT Installation and set up sequence 19 Filling the Water Tank 20 Set up Tea Extract 21 Set up Sweeten...

Страница 7: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 vii May 7 2002 Replacing Pump Tubing 36 Troubleshooting 39 Service Advisory 46 WARRANTY 47...

Страница 8: ......

Страница 9: ...e safety alerts This is the safety alert symbol used in this manual or on the machine The safety alert symbol is used to alert personnel to the potential of personal injury or damage to the machine Di...

Страница 10: ...ons to the machine The brewer can dispense hot water During the rinse operation water temperature can exceed 205 F Certain flow tubes in the brewer carry hot water Use Caution The heater tank contains...

Страница 11: ...g to repair the leak Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and death CAUTION PRECAUTIONS TO BE TAKEN IN STORAGE...

Страница 12: ...r rusted caps Open valve slowly If valve is hard to open discontinue use and contact your supplier Never apply flame or localized heat directly to any part of the cylinder High temperatures may damage...

Страница 13: ...Life Disconnecting the power supply or turning the power switch off for longer than 48 hours will result in a service call to reprogram the dispenser The battery will recharge itself when the power is...

Страница 14: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 6 May 7 2002...

Страница 15: ...clarity A metered quantity of cold water is added to the brewed tea mixture to produce finished tea The cold water reduces the temperature of the final product to approximately 90 F 32 C This tempera...

Страница 16: ...MENU key will scroll through five basic modes in a round robin fashion The menus and their order are DATA VIEW SET TIME STRENGTH SERVICE and SET UP To enter a selected mode the STOP key may be presse...

Страница 17: ...are no customers at the restaurant or a slow time of the day 1 Press the key to enter SET RINSE TIME Read the flash screens Press or key to move the cursor Press or keys to change settings Press key...

Страница 18: ...stalled as unsweetened the valve is overrid den and locked out and the controller skips over this function in Ser vice mode HOT BREW WATER VALVE STATE This screen displays the current state of the Hot...

Страница 19: ...es Fahrenheit and degrees Celsius HEATER RELAY STATE This screen displays the current state of the hot water heater safety relay ON OFF Pressing the LANGUAGE key will toggle the state between ON and O...

Страница 20: ...quence approxi mately 1 gram per second NOTE Tea extract may accumulate in the mix chamber Several dis penses may be required for tea extract to start flowing from the noz zle The allowed strength acc...

Страница 21: ...P HOT BREW WATER Holding the spigot open during this step will cause the brewer to do a 10 sec ond hot water only pour This is used to calibrate the amount of hot water to be dispensed during a normal...

Страница 22: ...displays may be scrolled by pressing or Keys Tea Pump State Tea extract flow may be initiated by pulling spigot handle Sweetener Valve State Sweetener flow may be initiated by pulling spigot handle H...

Страница 23: ...closed when the dispense lever is pulled forward This action initiates the dispense function through the control board Main Power Switch A manual power switch at rear of unit activates power to the d...

Страница 24: ...tal Specifications This brewer is intended for indoor installation only Operating Temperature Range 60 F to 110 F 10 C 38 C Storage Temperature Range 40 F to 130 F 4 C 54 C Electrical Requirement 15 a...

Страница 25: ...NATIONAL AND LOCAL CODES WARNING To avoid possible electrical shock make sure the brewer is properly grounded by connecting the earth ground cable in the power cord to any connection in the machine m...

Страница 26: ...r indoor installation only in a non harsh environment and out of direct sunlight CAUTION If the unit is exposed to freezing temperature water in the unit will freeze and may damage the unit LOOSE PART...

Страница 27: ...must not be emptied into the drip tray The overflow tube must first be disconnected from the vertical nozzle hidden behind the center support of the lower housing must remove lower door to expose The...

Страница 28: ...ressure is above 70 psi 3 Connect the 3 8 inch water filter outlet to the water inlet fitting on the back of the brewer Connect sweetener BIB to the 1 4 inch sweetener in let tube 4 Connect the Power...

Страница 29: ...15 to 20 minutes for the temperature of the water in the tank to reach the desired brewing temperature 160 F minimum to 180 F maximum 14 Press key and then the key to exit the TANK STATUS SET UP TEA E...

Страница 30: ...2 full turns clockwise to at which point maximum sweetness approx 15 brix is reached 7 Press and then the key to exit SETUP SWEETENER SET UP COLD WATER 1 Press the key to enter SETUP COLD WATER 2 Pul...

Страница 31: ...ll be cleaned Recommend a time when they open the restaurant in the morning This time should be when they normally clean their dispensing equipment or when there are no customers at the restaurant or...

Страница 32: ...NGTH mode and following the instructions on the display Range 5 Explain this procedure to the store manager 10 Press key and then key to exit SETUP TEA SYRUP 11 Press 4 times and then press key to exi...

Страница 33: ...handle down to start the flow of HOT water 1 of 5 will be displayed 6 When water stops flowing return the handle to the up position 7 The rinse cycle consists of 5 separate HOT water pours plus 1 norm...

Страница 34: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 26 May 7 2002 DIAGRAMS FIGURE 2 Plumbing Diagram...

Страница 35: ...Lipton Brewed Iced Tea Training Installation Service Manual May 7 2002 27 630460171 FIGURE 3 Wiring Diagram...

Страница 36: ...dispensed during a normal pour sequence 7 Press the Run key to return to normal operation Maintenance 1 Make sure CO2 and syrup supplies are maintained at all times 2 Remove syrup accumulation form t...

Страница 37: ...r line connector form the empty Bag in Box then connect sweetener line connector to a full box FIGURE 4 Bag In Box Sweetener System Diagram FIGURE 5 Sweetener Line Soldout Switch Inside the Unit Requi...

Страница 38: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 30 May 7 2002...

Страница 39: ...rge them in the detergent bucket and clean them with a brush or cloth 3 Remove each part and submerge them into the rinse bucket to remove the deter gent 4 Place the empty catch pitcher under the nozz...

Страница 40: ...rocedure Press the RINSE key to place the brewer in the rinse cycle mode In this mode the brewer will require user intervention to initiate each flush of hot water through the system This is done by o...

Страница 41: ...conds flush deadlegs for 10 seconds Blink LED warning flash backlight for 2 seconds flush deadlegs for 10 seconds Wait 80 seconds Wait 80 seconds Wait 80 seconds No No No Is water temperature above 16...

Страница 42: ...om the tea and sweetener containers 5 Remove the end caps located opposite the tubing connections on the bag in box connectors 6 Disconnect the Tea Sold Out Chamber from the clip on the back wall of t...

Страница 43: ...connectors and end caps into the two Sanitizing buckets that were pre pared above Repeat steps 8 and 9 to run the sanitizing solution through the sys tem 14 After all of the Sanitizing solution has b...

Страница 44: ...e cut length of pump tubing two hose clamps and instructions FIGURE 6 TEA EXTRACT PUMP REPLACING PUMP TUBING Replace pump tubing as follows 1 Remove pump motor assembly from the metal pump mounting br...

Страница 45: ...with each other FIGURE 8 7 Once the tubing is in place hold the tubing with one hand capture the lower part of the tubing with the outer housing then proceed to capture the shaft of the roller assembl...

Страница 46: ...May 7 2002 FIGURE 9 9 Insert the extract delivery tube into the pump tubing ends and secure them using the new hose clamps supplied in the kit Be sure to use pliers to squeeze and tighten the hose cl...

Страница 47: ...ion and help trouble shooting the beverage system FRESH BREWED SERVICE 1 866 Lip tonT 547 8668 liptontea ngbservice com IMPORTANT Only qualified Personnel should service internal components or electri...

Страница 48: ...In low power mode the tank will only heat for 20 seconds out of every minute 40 sec onds off 20 seconds on Full power to the tank will resume if the water tank temperature drops below 165 F Unit will...

Страница 49: ...n low power mode Signal voltage from the control module would supply 3 3 VDC to the low side terminals 3 red and 4 black of the relay The high side of the relay would handle the AC line voltage to the...

Страница 50: ...nder load the output should be between 22 and 25 VAC No lower than 22 VAC As viewed from the rear The left transformer supplies power to the KIP valves and flow control valves power is only switched t...

Страница 51: ...dash line on the outlet side of the body Take careful note of the orientation of the dash line on the body of the valve It may be in one position for Hot flow and in another position for Cold flow Ch...

Страница 52: ...ive valve micro switch No power to valve micro switch Control board failure Not in the run mode Replace With the wires disconnected check function of switch with Ohm meter check between the common and...

Страница 53: ...e too high Measure and adjust as necessary Unit will shut off heater relay if water temperature exceeds 192 F A high temperature message will appear on the data mode screen To turn the heater relay ba...

Страница 54: ...emperature as shown while in DATA mode is within 5 degrees of the hot water temperature as measured during a 15 second dispense from the spigot If not then there could be a bad temperature sensor wire...

Страница 55: ...FAX 55 21 593 1829 England Tything Road Alcester Warwickshire B49 6 EU England 44 789 763 101 FAX 44 789 763 644 France 71 Route De St Denis F 95170 Deuil La Barre Paris France 33 1 34 28 6200 FAX 33...

Страница 56: ...Lipton Brewed Ice Tea Dispenser Installation Service Manual 630460171 48 May 7 2002...

Страница 57: ...IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A Total Systems Commitment IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A Total Systems Commitment...

Страница 58: ......

Отзывы: