Lipton Brewed Iced Tea Training, Installation, & Service Manual
630460171
- 4
May 7, 2002
Shipping And Storage
K
EY
T
HINGS
T
O
K
NOW
•
Always unplug/disconnect the power to the dispenser before servicing.
•
Verify adequate water line pressures and volumes.
•
Verify water quality, optimum dispense taste may require water treatment.
•
Rinse water is very hot (160
°
- 205
°
F (71
°
- 82
°
C)).
CAUTION: PRECAUTIONS TO BE TAKEN IN
HANDLING: Protect cylinders from damage. Use a
suitable hand truck to move cylinders; do not drag,
roll, slide, or drop cylinders. Never attempt to lift a
cylinder by its cap; the cap is intended solely to
protect the valve. Never insert an object (e.g. wrench,
screwdriver, pry bar) into cap openings; doing so may
damage the valve and cause a leak. Use an adjustable
strap wrench to remove over-tight or rusted caps.
Open valve slowly. If valve is hard to open,
discontinue use and contact your supplier. Never
apply flame or localized heat directly to any part of the
cylinder. High temperatures may damage the cylinder
and could cause the pressure relief device to fail
prematurely and venting the cylinder contents. Never
strike an arc on a compressed gas cylinder or make a
cylinder part of an electrical circuit. For additional
information on storage and handling, refer to
Compressed Gas Association (CGA) pamphlet P-1,
“Safe Handling of Compressed Gases in Containers,”
available from the CGA.
CAUTION: Before shipping, storing, or relocating the
unit, product extract systems must be sanitized;
completion requires purging all sanitizing solution
from the systems. In addition, all liquids, after
sanitizing, must be purged from the unit. A freezing
ambient environment causes residual sanitizing
solution or water remaining inside the unit to freeze
resulting in damage to the internal components.
Содержание Brewed Iced Tea
Страница 2: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 ii May 7 2002...
Страница 4: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 iv May 7 2002...
Страница 8: ......
Страница 14: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 6 May 7 2002...
Страница 35: ...Lipton Brewed Iced Tea Training Installation Service Manual May 7 2002 27 630460171 FIGURE 3 Wiring Diagram...
Страница 38: ...Lipton Brewed Iced Tea Training Installation Service Manual 630460171 30 May 7 2002...
Страница 56: ...Lipton Brewed Ice Tea Dispenser Installation Service Manual 630460171 48 May 7 2002...
Страница 58: ......