44
326142000
BRIX
“A”
11.0
0.1358
11.5
0.1420
12.0
0.1481
12.5
0.1543
13.0
0.1605
13.5
0.1667
14.0
0.1728
14.5
0.1790
15.0
0.1852
15.5
0.1914
16.0
0.1975
GALLONS = “A” x SYRUP MINUTES
Using the above table, choose the “A” number that corresponds to your BRIX setting. Multiply the “A”
number by the syrup minutes reading to obtain the amount (gallons) of syrup used.
TABLE 8. “TOTALS” (DISPLAYED CYCLES AND HOURS TOTALS) MENU
ITEMS AFFECTED BY ERROR
MESSAGE
DISPLAY
ERROR
BEATER
MOTOR 1
BEATER
MOTOR 2
REFRIG 1
REFRIG 2
Motor 1
Low Current, < 109,
Sensed on motor one
OFF
OFF
Motor 2
Low Current, < 109,
Sensed on motor two
OFF
OFF
Motor 1
High current > 255,
Sensed on motor one
OFF
OFF
Motor 2
High current > 255,
Sensed on motor two
OFF
OFF
REFRIG
Maximum Run Time on compressor
OFF
OFF
OFF
OFF
SYRUP 1
Syrup Out Side One
OFF
SYRUP 2
Syrup Out Side Two
OFF
CO
2
OUT
CO
2
Out
OFF
OFF
H
2
O
H
2
O Out
*OFF
*OFF
SENSOR 1
Temp Sensor Inlet One
OFF
OFF
OFF
OFF
SENSOR 2
Temp Sensor Inlet Two
OFF
OFF
OFF
OFF
SENSOR 3
Temp Sensor Outlet
OFF
OFF
OFF
OFF
* The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss
has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and
carbonator will stop.
TABLE 9. DISPLAYED ERROR CONDITIONS
Содержание 326142000
Страница 23: ...16 326142000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 33: ...26 326142000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 37: ...30 326142000 FIGURE 5 OPERATING CONTROLS ...
Страница 38: ...31 326142000 FIGURE 6 UNIT INTERNAL COMPONENTS ...
Страница 59: ...52 326142000 FIGURE 12 WATER STRAINER SCREEN AND DOUBLE LIQUID CHECK VALVE ...
Страница 66: ...59 326142000 FIGURE 16 REFRIGERATION FLOW DIAGRAM ...
Страница 67: ...60 326142000 FIGURE 17 WIRING DIRGRAM ...
Страница 77: ...326142000 70 4 5 6 7 8 11 12 14 15 79 84 85 87 88 115 117 118 4 FIGURE 20 FCB FLOW DIAGRAM ...