Installation and service manual: Postmix tower
Ribbon
54
Cornelius Deutschland GmbH
Document no. TD0000100
Version: 06/11/2017, Index 0
7.13
Replacing the valves
1.
Remove the panel (Figure 67/1).
2.
Remove the valve mount (Figure 67/2).
3.
Lift and remove the valve (Figure 68/1) from the valve
assembly (Figure 68/2) in an upward motion.
Prerequisites
Reference
The valve assembly has been removed.
.
Spare parts
ID/reference
Qty/
amount
Comment
Syrup valve
620056892S
8
Flavour valve
620056892F
4
Water valve
620056892W
2
Quad ring
620059773
14
O-ring
740001852
14
Lubricating grease
Compliant with food law
2
1
Figure 67
1
2
Figure 68